Performance Data Sheet; Interior Water Filtration System - Maytag MFI2570FEZ07 Instrucciones Para El Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Substance Reduction Aesthetic Effects Influent Challenge Concentration
Chlorine Taste/Odor
Particulate Class I*
Contaminant Reduction
Lead***: @ pH 6.5 / @ pH 8.5
Mercury: @ pH 6.5 / @ pH 8.5
Asbestos
Cysts†
Turbidity
Atrazine
Benzene
Carbofuran
Lindane
P-Dichlorobenzene
Tetrachloroethylene
Toxaphene
Atenolol
Endrin
Ethylbenzene
o-Dichlorobenzene
2,4 - D
Carbamazepine
DEET
Linuron
Meprobamate
Metolachor
Trimethoprim
Bisphenol A
Estrone
Nonylphenol
Ibuprofen
Naproxen
Phenytoin
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental contaminants are those
compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/
perception of drinking water quality.
It is important that operational, maintenance, and filter replacement requirements
be carried out for the product to perform as advertised. Property damage can
occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter UKF8001, Part #EDR4RXD1/EDR4RXD1B. 2015
suggested retail price of $49.99 U.S.A./$49.95 Canada. Prices are subject to
change without notice.
The filter monitor system measures the amount of water that passes through the
filter and alerts you when it is time to replace the filter. To learn how to check the
water filter status, see "Using the Controls" or "Water Filtration System" in the
User Instructions or User Guide.
After changing the water filter, flush the water system. See "Water and Ice
Dispensers" or "Water Dispenser" in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing was
performed under standard laboratory conditions, actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and local laws and
regulations.
*Class I particle size: >0.5 to <1 um
***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
†Based on the use of Cryptosporidium parvum oocysts
††Fibers greater than 10 um in length
NSF is a registered trademark of NSF International.
®

PERFORMANCE DATA SHEET

Interior Water Filtration System

Model UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
2.0 mg/L ± 10%
At least 10,000 particles/mL
Influent Challenge Concentration
0.150 mg/L ± 10%
0.006 mg/L ± 10%
10
7
to 10
8
fibers/L
††
50,000/L min.
11 NTU ± 10%
0.009 mg/L ± 10%
0.015 mg/L ± 10%
0.080 mg/L ± 10%
0.002 mg/L ± 10%
0.225 mg/L ± 10%
0.015 mg/L ± 10%
0.015 mg/L ± 10%
200 ± 20%
0.006 mg/L± 10%
2.1 mg/L ± 10%
1.8 mg/L± 10%
0.210 mg/L ± 10%
1400 ± 20%
1400 ± 20%
140 ± 20%
400 ± 20%
1400 ± 20%
140 ± 20%
2000 ± 20%
140 ± 20%
1400 ± 20%
400 ± 20%
140 ± 20%
200 ± 20%
Maximum Permissible Product Water
Concentration
50% reduction
85% reduction
Maximum Permissible Product Water
Concentration
0.010 mg/L
0.002 mg/L
>99%
>99.95%
0.5 NTU
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.0002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
30 ng/L
0.002 mg/L
0.7 mg/L
0.6 mg/L
0.07 mg/L
200 ng/L
200 ng/L
20 ng/L
60 ng/L
200 ng/L
20 ng/L
300 ng/L
20 ng/L
200 ng/L
60 ng/L
20 ng/L
30 ng/L
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certified for
cyst reduction may be used on disinfected waters that may contain filterable
cysts. EPA Est. No. 10350-MN-005.
Refer to the "Warranty" section (in the User Instructions or User Guide) for the
Manufacturer's limited warranty, name and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average% Reduction
97.6%
98.8%
Average% Reduction
99.3% / 99.3%
95.1% / 95.0%
>99%
99.99%
98.1%
94.4%
96.6%
86.8%
98.8%
99.7%
96.0%
93.8%
>95.9%
96.7%
99.9%
99.9%
97%
>98.6%
>98.5%
>96.8%
94.6%
98.3%
>96.4%
99.4%
>96.7%
>98.9%
92.9%
>96.3%
>94.8%
City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.78 gpm (2.95 L/min.) @ 60 psi
17

Publicidad

Tabla de contenido
loading

Tabla de contenido