2. Take out the row of flake covers by snapping one end up and pulling forward.
3. Remove the slideway from the water sump.
4. Find the sprinkler arm and raise it. Disconnect
it from the water tube which is
connected
at the back of the sprinkler arm.
/
/
/
.
A de-scaling
solution can be prepared in a plastic basin with Nu-Calgon
Nickel-Safe
Ice Machine Cleaner.
Mix 4 ounces of the ice machine cleaner per gallon of warm
water.
Remove the sprinkler arm from the interior.
Thoroughly
clean the sprinkler arm by
soaking it in the basin filled with the de-scaling
solution until it is free of any deposit;
use a soft brush to remove any thick or stubborn residue and to help the dissolving
action. Rinse under a stream of tap water.