Electrical connection

GB
! ! ! ! ! Ovens equipped with a three-pole power supply
cable are designed to operate with alternating
current at the voltage and frequency indicated on
the data plate located on the appliance (see below).
Fitting the power supply cable
L
N
wire to the terminal marked
3. Secure the cable by fastening the clamp screw.
4. Close the cover of the terminal board.
Connecting the electricity supply cable to the
mains
Install a standardised plug corresponding to the
load indicated on the data plate (see table).
The appliance must be directly connected to the
mains using an omnipolar switch with a minimum
contact opening of 3 mm installed between the
appliance and the mains. The switch must be
suitable for the charge indicated and must comply
with current electrical regulations (the earthing wire
must not be interrupted by the switch). The supply
cable must be positioned so that it does not come
into contact with temperatures higher than 50°C at
any point.
! ! ! ! ! The installer must ensure that the correct electrical
connection has been performed and that it is fully
compliant with safety regulations.
16
1. Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see diagram).
2. Install the power
supply cable by
loosening the cable
clamp screw and the
three wire contact
screws L-N-
.
Connect the wires to
the corresponding
terminals: the Blue wire
to the terminal marked
(N), the Brown wire to
the terminal marked (L)
and the Yellow/Green
(see diagram).
Before connecting the appliance to the power
supply, make sure that:
• the appliance is earthed and the plug is compliant
with the law;
• the socket can withstand the maximum power of
the appliance, which is indicated on the data
plate (see below);
• the voltage is in the range between the values
indicated on the data plate (see below);
• the socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.
! ! ! ! ! Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.
! ! ! ! ! The cable must not be bent or compressed.
! ! ! ! ! The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
! ! ! ! ! The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
The manufacturer declines any liability should
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
these safety measures not be observed.
APPLIANCE SPECIFICATIONS
width 43.5 cm
Dimensions
height 32 cm
depth 41.5 cm
Volume
58 l
voltage: 220-240V ~ 50/60Hz
Electrical
maximum power absorbed
connections
2800W
Directive 2002/40/EC on the
label of electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
ENERGY LABEL
Conventional;
Declared energy consumption for
Forced convection Class –
heating mode:
Grill.
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC dated 12/12/06
(Low Voltage) and subsequent
amendments – 2004/108/EEC
dated 15/12/04 (Electromagnetic
Compatibility) and subsequent
amendments - 93/68/EEC dated
22/07/93 and subsequent
amendments.
2002/96/EEC and subsequent
amendments.
1275/2008 stand-by/off mode.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fn 36Fng 36Fa 36.1Sv 39 naxSv 39 nabFn 46 t xa

Tabla de contenido