INSTALLATION INSTRUCTIONS
Faucet Tower Installation
Remove the plug from the top of the fridge cabinet
by twisting and pulling out. Save the plug for later
use.
Unravel the beer line (clear hose) from the faucet
tower and insert the beer line and wing nut through
the uncovered hole on top of the appliance.
Lock the beer tower assembly to the top of the
appliance and make sure to position the beer faucet
so it is aligned with the front of the cabinet.
The rubber gasket can be used to make the
connection between the tower and the cooler
tighter if needed. If the beer tower will not turn
to lock in place, try removing the rubber gasket.
The rubber gasket may not be required in all unit
confi gurations.
If the tower faucet is leaking or if the beer is very
foamy, ensure that the washers inside the faucet are
intact. Replace the washers with spare parts from
the accessory bag, if necessary.
Faucet Components
1. Faucet handle
2. Chrome faucet collar
3. Faucet bonnet
1
4. Friction washer
5. Ball washer
6. Stainless steel faucet lever
7. Chrome faucet body
8. Faucet gasket
9. Chrome shaft assembly
2
3
4
5
6
9
8
7
Protective Metal Plate Installation
The protective metal plate should be installed on the
bottom of the inside of the cabinet. This plate should
always be installed when a keg is in place to protect
the fl oor of the cabinet against damage.
Beer Keg Installation
Position the beer keg directly in front of the open
door. Using keg handles only, carefully lift the beer
keg. Lift the front of the keg just enough so the front
end of the keg is resting on the front edge of the keg
cooler bottom cabinet. Grasp the keg handles and
slide the keg all the way into the cabinet.
Note: Two people should lift the keg to avoid back
injury.
Connecting the Air Line to the Coupler
Attach the end of the air line (colored) hose to the
hose connection on the side of the coupler. Ensure
that the check valve is inserted into the connection,
number 4 on the image below.
If, after assembly, beer will not fl ow, ensure that the
check valve has a small hole in it. If there is no hole
in the check valve then CO
and the beer will not fl ow.
Connecting the Beer Tower to the Coupler
Ensure all washers are properly inserted into the
coupler. Ensure the valve spool plastic rod is in
place inside the coupler. Place the wing nut attached
to the end of the beer line into the top of the coupler,
turning until tight.
If, after assembly, the beer is very foamy, it most
likely means that a connection in the coupler is
leaking and air is entering the lines. Double check
all connections in the coupler and replace the
washers from the accessory bag as necessary.
7
cannot enter the line
2