• When a change takes place in the operation set mode, the adjustment will occur
in ON/OFF mode until Tset is reached the fi rst time, to thus achieve the confi gured
conditions as quickly as possible.
IMPORTANT: the PROPORTION confi guration will not have any effect if operation
is SUMMER type; in this case, the adjustment mode will always be the ON/OFF
type.
ADVANCED PROGRAMMING
• TThe operating parameters common to all adjustment zones are confi gured in this
menu, designated by the symbol
° confi guration of each adjustment zone;
° existence of external sensor;
° ºC/ºF measurement unit;
° unit bus address.
Confi guration of each adjustment zone
• On accessing the menu, the fi rst zone Z1confi guration
screen will be shown.
• Use the key
to sequentially display the other zones.
• The following confi guration parameters can be entered:
° the temperature sensor associated with the zone
may be:
internal (INT)
external (EXT)
remote over the bus (BUS)
° the actuator associated with the zone can be:
relay (REL)
wireless (RF)
remote over the bus (BUS)
° a description that identifi es the zone name.
Note: a Tx.Athena radio module is required to program the remote via the bus
and the chronothermostat must be installed on the wall bracket.
• If the sensor chosen for the adjustment zone is an Athena.Temp Temp sensor, it
will be confi gured in this phase.
• If the sensor chosen for the adjustment zone is an RX4-8A remote actuator, it will
be confi gured in this phase (both wireless and via the bus).
:
- 58 -
Athena
Instruction Manual
ADV