3 Product description
Welding current at 25° C
X=50 %
X=60 %
X=100 %
Welding current range
Idle voltage
Protection type
Insulation class
Type of cooling
Dimensions (lxwxh)
Weight
Standards
Mains connecting cable
Length of the supply line
Supply voltage
Internal operating voltage
Power consumption
Tab. 1
Technical data according to IEC 61000-3-11
Ambient temperature
Relative humidity
Tab. 2
Ambient conditions during operation
Storage in a closed environment, ambient temperature
Ambient temperature for transport
Relative humidity
Tab. 3
Ambient conditions for transport and storage
3.2 Abbreviations
iROB
iFEED Basic / Comfort
iCOOL
iCONTROL
iBRACKET
iCLAMP
iSPOOL
RI
Tab. 4
Abbreviations
Units of measurements in drawings or diagrams
Tab. 5
Dimensions
EN - 8
iROB P400
iROB P400 MV
400 A
3 - 400 A
624x282x474 mm
29,9 kg
EN 60974-1, EN 60974-10
4x4 mm² / H07RN-F4G4 4x6 mm² / H07RN-F4G6 4x4 mm² / H07RN-F4G4
400 VDC
400 VDC / 230 VDC
Robot welding power source
Wire feeder
Coolant recirculator for the robot welding power source
Remote control for the setup of the robot welding power source
Mounting platform for the wire feeder
Fastener for intermediate cable assembly on the robot
Fastening and support for K300 wire spools on the robot
Robot interface
Millimetres [mm]
iROB P500
500 A
470 A
3 - 500 A
73 Vdc
IP23
H
AF / Fan
31 kg
30,9 kg
5 m
400 VDC
24 VDC
1,5 kW
- 10 °C bis + 40 °C
up to 50 % at 40 °C
up to 90 % at 20 °C
- 25 °C to + 55 °C
- 25 °C to + 55 °C
up to 90 % at 20 °C
iROB