MANUAL DE USUARIO - OPTIMA-31 10K / 20K / 30K
13.- ESPECIFICACIONES TECNICAS (1/2)
ONLINE UPS 31
Capacity / Capacidad
Input-Output / Entrada-Salida
INPUT / ENTRADA
Phase / Fases
Input Range / Rango de Entrada
Max. Current / Corriente Max.
Frequency Range / Rango de Frecuencia
Power Factor / Factor de Potencia
THDi
Slew Rate / Segumiento de Frecuencia:
OUTPUT / SALIDA
UPS 31 230Vac (with Internal batt.)
Voltage Regulation / Regulación de Salida:
Frequency / Frecuencia (Batt. Mode)
Current Crest Ratio / Factor de Cresta
THDv
Dynamic Accuracy / Regulación Carga Variable
Transfer Times / Tiempos Transferencia:
Waveform / Forma de Onda
Power Output / Salidas
DC Offset / Componente DC
OVERLOAD / SOBRECARGA
AC Mode / Modo Normal
Battery Mode / Modo Batería
EFFICIENCY / EFICIENCIA
Eco Mode (100%/75%/50%/25% load)
AC Mode / Modo AC (100%/75%/50%/25% load)
Battery / En Batería (100%/75%/50%/25% load)
Inverter Efficiency / Eficiencia Inversor
PROTECTIONS / PROTECCIONES
Surge / Contra Picos
Short Circuit / Contra Cortos en la salida
Input Current / Corriente de Entrada
Starting Time / Tiempo de Arranque
BATTERIES / BATERIAS
Type and Qty / Tipo y Cantidad
Internal Battery Pack / Baterías Internas
External batt cabinet / Baterías Externas
Typical Recharge T. / T. de Recarga
Charging Amps / Corriente de Carga
Charging VDC / Voltaje Cargador (Floating)
Temp. Compensation / Compensación Temp.
Shutdown battery Voltage / Voltaje DC Apagado
www.xmart-ups.com
31 10K
10.000VA / 8.000W
3Ph - 1Ph
L-N: (176Vac-300Vac) @ 100% load
L-N: (110Vac-300Vac) @ 50% load
17A rms per phase
40 - 70 Hz
> 0.99 @ 100%load
< 5% @ 100% load
1 Hz / s
1Ph + N + G (208/220/230/240Vac L-N) (*N1)
50 Hz +/- 0.1 Hz / 60 Hz +/- 0.1 Hz
< 2% @ Linear Load / Carga Lineal
<5% @ No Linear Load / Carga no Lineal
<5% (load variations 0%-100% & 100%-0% R Load)
Sine Wave / Sinusoidal Pura
Terminal Block / Regleta de Conexión
50mV max.
(100%-110%: 10min) (110%-130%: 1m) (>130%: 1s)
(100%-110%: 30s) (110%-130%: 10s) (>130%: 1s)
97% inverter @ 100% load
In all lines / En todas las líneas (L1/L2/L3-N, L1/L2/L3-G, N-G): > 1500J (10/1000us)
100% of nominal current / 4s (then cut-off / luego apagado de salida)
Sealed maintenance free / Sellada libre de mantenimiento (VRLA)
12V/9AH (1 set x 20 pcs)
Option: 2 sets x 20pcs
4-6h (90%)
4.0 A (Max.)
273.0 VDC
120mV/ºC per battery (Input Air Temp/ Temp. Aire entrada: 25-50ºC)
214VDC (0-30% load) / 204VDC (30-70% load) / 192VDC (load >70%)
31 20K
20.000VA / 16.000W
3Ph - 1Ph
3Ph + N + G
380V (L-L) / 220V (L-N)
34A rms per phase
40 - 70 Hz
> 0.99 @ 100%load
< 5% @ 100% load
1 Hz / s
+/- 1%
3:1 @ 100% load
0 ms
50mV max.
97% / 95% / 93% / 92%
91% / 90% / 88% / 87%
90% / 89% / 87% / 86%
Circuit Breaker / Disyuntor
7s - 10s (@ 100% load)
12V/9AH (2 sets x 20pcs)
Option: 2 sets x 20pcs
4-6h (90%)
4.0 A (Max.)
273.0 VDC
V. 170502-OPT-31 10K/20K/30K (SPANISH) -
31 30K
30.000VA / 24.000W
3Ph - 1Ph
51A rms per phase
40 - 70 Hz
> 0.99 @ 100%load
< 5% @ 100% load
1 Hz / s
50mV max.
12V/9AH (3 sets x 20pcs)
Option: 3 sets x 20pcs
4-6h (90%)
8.0 A (Max.)
273.0 VDC
46