item by rotating the encoder (light background) and press the encoder 2x to set the gate mode as desired by rotating the encoder to AUTO
(automatic), MANUAL (manual) or OFF (disabled). Confirm the entry by pressing the encoder. If you press the encoder only 1x, you can exit
this menu item without changes by rotating the encoder and selecting the arrow symbol (light background) and confirm by pressing the
encoder. To return to the main display, select EXIT now by rotating the encoder (light background) and confirm by pressing the encoder. After
approximately 10 seconds of inactivity, the display will automatically return to the main screen.
THRESHOLD
Manual adjustment of the threshold for the gate function (see menu item MODE). Adjust the threshold so that ambient noise does not
automatically activate a microphone station, and so that the activation of a microphone station by a speaker remains possible. This setting
applies to all devices and can only be carried out on a device that is configured as a master unit, if two to five units are daisy-chained.
Pressing the pressure rotary encoder PUSH TO ENTER will take you to the selection menu for system settings. Now select the THRESHOLD
menu item by rotating the encoder (light background) and press the encoder 2x to set the threshold level as desired from 01 to 10 by
rotating the encoder (1 = lowest threshold, 10 = highest threshold). Confirm the entry by pressing the encoder. If you press the encoder only
1x, you can exit this menu item without changes by rotating the encoder and selecting the arrow symbol (light background) and confirm by
pressing the encoder. To return to the main display, select EXIT now by rotating the encoder (light background) and confirm by pressing the
encoder. After approximately 10 seconds of inactivity, the display will automatically return to the main screen.
HOLD TIME
Manual adjustment of the hold time for the gate function (see menu item MODE). Set the hold time as desired (0.1 - 1s). The microphone
station remains active for the duration of the set hold time, even after muting the audio signal. This setting applies to all devices and can
only be carried out on a device that is configured as a master unit, if two to five units are daisy-chained.
Pressing the pressure rotary encoder PUSH TO ENTER will take you to the selection menu for system settings. Now select the HOLD TIME menu
item by rotating the encoder (light background) and press the encoder 2x to set the hold time as desired from 0.1 to 1s by rotating the encoder.
Confirm the entry by pressing the encoder. If you press the encoder only 1x, you can exit this menu item without changes by rotating the
encoder and selecting the arrow symbol (light background) and confirm by pressing the encoder. To return to the main display, select EXIT now
by rotating the encoder (light background) and confirm by pressing the encoder. After approximately 10 seconds of inactivity, the display will
automatically return to the main screen.
SETUP
10