CAUTION:
EN
EN
• To prevent damage, do not operate
Forward/Reverse lever until the bit
comes to a complete stop.
Forward Rotation Switch
Operation
1. Push the lever for forward rotation.
. Depress the trigger switch slightly to start
the tool slowly.
. The speed increases with the amount of
depression of the trigger for efficient tight-
ening of screws. The brake operates and
the bit stops immediately when the trigger
is released.
4. After use, set the lever to its center posi-
tion (switch lock).
Reverse Rotation Switch
Operation
1. Push the lever for reverse rotation. Check
the direction of rotation before use.
. Depress the trigger switch slightly to start
the tool slowly.
. After use, set the lever to its center posi-
tion (switch lock).
CAUTION:
• To eliminate excessive temperature
increase of the tool surface, do not
operate the tool continuously using two
or more battery packs. Tool needs cool
off time before switching to another
pack.
Tightening confirmation lamp
• The tightening confirmation lamp can be
used to check whether the torque control
function was activated.
Tool status
Tightening complete
(with torque control
function operation)
• Tightening not complete
• Tightening complete
with retightening within 1
second
The automatic stop
function has been
activated.
Control Panel
(1) The torque control function
• The torque control function calculates the
Lamp display
Green
(For approx.
seconds)
Red
(For approx.
seconds)
Red
(For approx.
minutes)
- 10 -
CAUTION:
• When the tool stops automatically after
the switch is released during impact-
mode tightening and then reengaged
within 1 second, the red lamp will light up
to indicate the risk of excessive torque
application as a result of retightening.
NOTE:
• The tightening confirmation lamp will not
turn on under the following conditions:
• When the torque clutch is set to "F"
• During reverse rotation operation
• The lamp turns off when the tool is in
operation.
(1)
load from the motor's rotational angle during
the hammer impact and determines that the
bolt has been properly seated when a pre-
set load value is exceeded. Driving is then
automatically stopped after a preset number
of impacts have been delivered to the bolt.
CAUTION:
• Always check the tool's tightening torque
before use. The required adjustment
is dependent on the type of threaded
connection and can be best determined
by practical trials. Check the trial screw-
ings with a torque wrench. Improper tool
operation may result in excessive or
inadequate tightening.
• Always operate the tool with the switch
fully depressed. The torque control
function will not operate when the
switch is not sufficiently depressed, pre-
venting the tool from stopping automati-
cally.
• In work where a heavy load comes to
bear during tightening, the load may be
interpreted as the seating of the bolt,
preventing the bolt from being com-
pletely tightened.
• Repeated tightening of the same bolt
may break the bolt or deform the mate-
rial into which the bolt is being driven as
a result of excessive tightening.
()
()