Error Display - Panasonic EYFPA1J Manual De Instrucciones

Ocultar thumbs Ver también para EYFPA1J:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Error Display

In the event of a tool or battery pack malfunction, the control panel will display an error message.
Please check the tool or battery pack as described in the following chart before having them
serviced.
Display
NOTE:
• When the tightened bolt is further tightened or loosened, the overload protection function (E)
may be activated.
Likely cause
Setting error
The battery pack is too hot.
The tool is too hot to operate.
The contacts that connect the
battery pack and tool are dirty.
The battery pack has not been
properly inserted into the tool.
The pins on either the tool or
battery pack have worn down.
Overload, Motor failure. etc.
Tool circuit malfunction, failure,
etc.
The tool is unable to communi-
cate with the Assembly Quali-
fier while the radio signal range
limitation function is on.
Re-initialize the tool using the
remote control. (See page 1.)
Stop work and allow the battery
pack to cool before resuming use
of the tool.
Stop work and allow the tool to
cool before resuming use.
Remove any dirt.
Insert the battery pack firmly into
the tool.
Replace the battery pack.
Stop using the tool immediately.
• Verify that the tool has been
properly registered to the Assem-
bly Qualifier.
• Verify that the Assembly Qualifi-
er's group setting has been con-
figured correctly.
• Improve the reception state, for
example by moving the Assem-
bly Qualifier closer to the tool.
- 17 -
Corrective action
EN
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Eyfpa1jr

Tabla de contenido