3 CURV 500 satellites per SmartLink adapter 70 V = maximum
of 8 SmartLink adapters (8 x 60 W = 480 W max.)
Speaker preset 3xC500-70V
4 CURV 500 satellites per SmartLink adapter 70 V = maximum
of 6 SmartLink adapters (6 x 80 W = 480 W max.)
Speaker preset 4xC500-70V

CONFIGURATION OF SPEAKER OUTPUTS

The speakON-compatible sockets and the terminal block connectors are wired in parallel. In bridge mode (BTL = Bridge Tied Load) / 70 V
operation, the speakON-compatible sockets B and D may NOT be assigned; this also applies to the minus pins of the terminal block connec-
tions. For signal control, please note that the input routing can be freely configured (see ROUTING). A combination of two bridged amplifier
channels (bridge mode) for controlling 70 V SmartLink adapters and controlling, for example, two CURV 500 ISUB speakers is possible in
normal mode (e.g. channel A/B bridge mode – channels C and D in normal mode). Select the appropriate speaker presets.
1
8
1
6
3 x LDCURV500SAT
LDCURV500SLAT
4 x LDCURV500SAT
LDCURV500SLAT