Continuity Testing; Battery Measurement - EGAmaster EGAtronik 51259 Manual De Instrucciones

Multímetro digital para automóviles
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Warning!
To avoid possible damage to the Meter and to the device under test, disconnect circuit power
and discharge all high-voltage capacitors before testing diodes and continuity.
To avoid harm to yourselves, never attempt to input an effective voltage over 60V in DC or
30V in AC.
To test for continuity, connect the Meter as below:
1. Insert the red test lead into the
2. Set the rotary switch to
3. Connect the test leads across with the object being measured.
- The buzzer does not sound when the resistance value is >100Ω.
- The buzzer sounds continuously when the resistance value is ≤10Ω. The circuit is in good
condition.
- The buzzer may or may not sound when the resistance value is between 10Ω ~100Ω.
4. The nearest value of the tested circuit show on the display, the unit is Ω.
Note
- Open-circuit voltage is approx. 3V.
- When continuity testing has been completed, disconnect the connection between the testing
leads and the circuit under test.
Warning!
To avoid harm to yourselves, never attempt to input
an effective voltage over 60V in DC or 30V in AC.
To test the battery, proceed as follows:
1. Insert the red test lead into the
terminal.
38
F. CONTINUITY TESTING (SEE FIGURE 7)
terminal and the black test lead into the COM terminal.
.
G. 12V BATTERY MEASUREMENT (SEE FIGURE 8)
(figure 8)
terminal andthe black test lead into the COM

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido