Risk Of Electromagnetic Interference And Possible Remedies - Gima SUPER VEGA Manual De Istrucciones

Aspirador quirúrgico - 1 l
Ocultar thumbs Ver también para SUPER VEGA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
VACUUM Port
PATIENT Port
ON/OFF Switch
MAKE SURE THAT CHILDREN AND/OR MENTALLY ILL PEOPLE DO NOT USE THE DEVICE WITHOUT ADULT

RISK OF ELECTROMAGNETIC INTERFERENCE AND POSSIBLE REMEDIES

The SUPER VEGA SUCTION ASPIRATOR is an electro-medical device that requires particular precautions regarding electro-
This section contains information regarding the conformity of the compliance with the EN 60601-1-2 Standard.
magnetic compatibility and which must be installed and commissioned according to the electro-magnetic compatibility
information supplied. Portable and mobile radio communication devices (mobile phones, transceivers, etc.) may interfere with
the medical device and should not be used in close proximity with, adjacent to or on top of the medical device. If such use is
necessary and unavoidable, special precautions should be taken so that the electro-medical device functions properly in its
intended operating configuration (for example, constantly and visually checking for the absence of anomalies or malfunctions).
The use of accessories, transducers and cables different to those specified, with the exception of transducers and cables sold by
the appliance and system manufacturer as spare parts, can lead to an increase in emissions or in a decrease of the immunity of
the device or system. The following tables supply information regarding the EMC (Electromagnetic Compatibility)
characteristics of the electro-medical device.
The SUPER VEGA SUCTION ASPIRATOR is intended for use in the electromagnetic environment specified below.
The customers or the user of the SUPER VEGA SUCTION ASPIRATOR should assure that it's used in such an environment.
Emissions test
Irradiated / Conducted emissions
CISPR11
Irradiated / Conducted emissions CISPR11
Harmonic emissions EN 61000-3-2
Voltage fluctuations / flicker emissions
EN 61000-3-3
NEVER USE THE DEVICE WITHOUT JAR AND / OR PROTECTION FILTER
Guidance and manufacturer's declaration – electromagnetic Emissions
Compliance
Group 1
Class [B]
Class [A]
Complies
Autoclavable Silicone Tube
SURVEILLANCE
The SUPER VEGA SUCTION ASPIRATOR only used RF
Electromagnetic environment - guidance
energy only for its internal functioning. Therefore, its RF
emissions are very low and are not cause interference in
The SUPER VEGA SUCTION ASPIRATOR can be used in all
proximity of any Electronic appliances.
environments, including domestic and those connected
directly to the public mains distribution that supplies power
to environments used for domestic scopes.
18
Antibacterial Filter
Conical Fittings
Vacuum Regulator knob
Vacum Indicator (kPa/Bar)
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

28211

Tabla de contenido