IMPORTANT:
• If wall mounted, make sure the fixture is mounted with the
sensor below the lamp heads.
• If eave mounted, mount the fixture with sensor facing away
from the house wall. Rotate the sensor so the controls face the
ground.
4. Push the rubber plug firmly into the mounting bolt hole on the
light fixture (see Figure 5).
5. Caulk around mounting plate and mounting surface with silicone
weather sealant (see Figure 6).

TESTING AND ADJUSTMENTS

CAUTION: To avoid water damage and risk of electrical
shock, motion sensor controls must be facing the ground
when installation is complete.
1. Turn on the circuit breaker and wall switch.
Note: The motion sensor has a 1 minute warm up period before it
will detect motion. When power is first turned on wait 1 minute.
2. Slide the CHANNEL switch to OFF, the sensitivity (SENS)
switch to the "L" position, and the DUALBRITE switch to the
TEST position (see Figure 7). Note: The TEST mode overrides
the photocell (daylight shutoff feature) and allows the light fixture
to be tested day or night.
3. Walk through the coverage area noting where you are when the
lights turn on. Also, the red LED behind the motion sensor lens
will flash several times when motion is detected (see Figure 8).
4. Stop, wait for the light to turn off (8 seconds), and then begin
walking again. Continue this process until the detection zone has
been established.
5. If needed, gently grasp the motion sensor and move it from side
to side or up and down to adjust the detection zone.
6. If needed, gently grasp the lamp heads and move them from side
to side or up and down to adjust the light coverage area.
7. Adjust the sensitivity (SENS) switch as needed ("L", "M", "H").
Sensitivity set too high may increase false triggering.
LINKING LIGHTS
This light has been designed with link technology which allows
multiple lights to be connected together wirelessly. Linked lights
can be grouped into one of three possible channels to create linked
zones of lighting. See Link Technology section for more information.
1. Slide the CHANNEL switch to the desired channel (A, B, or
C) on all lights to be linked together.
2. Slide the DUALBRITE switch to the TEST position on all of
4
To see operational and troubleshooting information and videos,
go to www.hzsupport.com
Figure 5
Figure 6
A
B
OFF
C
CHANNEL
L
M
H
SENS
4H
OFF
TEST
D2D
DUALBRITE
Figure 7
Figure 8
209735-01