in front of ALL linked lights. The light will then return to the reduced light level. Once the DualBrite timer runs out,
the light will turn ON only when motion is detected by any of the linked lights. Selecting OFF disables the DualBrite
feature, however the motion sensing features will continue to work.
For linked lights, the first light to sense darkness will turn on all other linked lights on the same channel if the DualBrite
timer has been turned ON on each linked light. The lights will turn OFF independently of each other and may not turn
OFF at exactly the same time.
MANUAL MODE
Manual mode overrides the motion sensor and "ON-TIME" control so the light will operate full bright. This feature
only works at night and only for one night at a time. The motion sensor will reset to motion sensing mode after 6 hours
or sunrise, whichever comes first. Manual mode can be toggled on and off using a wall switch. Note: If the power to the
light fixture is off for more than 5 seconds, allow the motion sensor to warm up prior to switching to manual mode.
1. Ensure the power to the light is ON and the sensor has warmed up (60 seconds).
2. To turn manual mode on, switch the power OFF–ON–OFF–ON at the wall switch within 5 seconds.
3. To turn manual mode off, switch the power OFF–ON–OFF–ON at the wall switch within 5 seconds.
IMPORTANT: If manual mode does not turn ON or OFF, use a slower pace turning the power ON and OFF at the wall
switch while staying within 5 seconds.
OFF
ON
OFF
ON
Less than 5 seconds
CARE AND CLEANING
• To prolong the original appearance, clean the light fixture with clear water and a soft, damp cloth only.
• Do not use paints, solvents, or other chemicals on this light fixture. They could cause a premature deterioration of the
finish. This is not a defect in the finish and will not be covered by the warranty.
• Do not spray the light fixture with a hose or power washer.
• To clean the camera lens, use a dry, microfiber cloth only.
SPECIFICATIONS
Range ...................................................Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle.......................................Up to 180°
Power Requirements .............................120 VAC, 60 Hz
Operating Modes .................................TEST, MOTION ACTIVATED, and MANUAL MODE
ON-Timer ............................................5 minutes (non-adjustable)
Test Timer ............................................8 Seconds
Manual Mode Timer ............................Maximum 6 Hours
Sensitivity (SENS) ..............................."L", "M", "H"
Link Technology Range .......................Up to 100 ft (30.5 m) [varies with surrounding obstructions].
6
209735-01
To see operational and troubleshooting information and videos,
go to www.hzsupport.com