10
Adjustments
• No adjustment is necessary. This is carried out
in our workshops.
• However, in the event of knocks, loosening of
bolts, rough handling when pivoting the head:
* adjust screw
(K) [
SEE FIG.9
* check the squarring (for straight line cuts);
* and lock the lock-nut screw
on front and rear arms).
11
Maintenance
(the motor must be stopped)
Before carrying out any operation
disconnect the machine from the
mains
•
Clean the machine daily.
• Empty regularly the tank to remove muddy
deposits which could clog the pump and thus
cause premature wear.
• Wash the tray with plenty of water.
• Clean the pump.
• Store in a dry place
• Clean the rails with particular attention.
Store in a dry place, not accessible to
children.
Maintain the tools carefully.
FAULT FINDING
In the event of faulty operation refer to the tables
below to find a solution.
].
(K) (adjustment
•
The machine does not work
CAUSES
Not
plugged
in
properly
or
cable
damaged
No mains voltage
Switch
defective,
motor cable damaged
Motor
faulty
(no
power, unpleasant
smell)
•
Difficult starting
CAUSES
Single phase motor
starting condenser
•
The pump does not start
CAUSES
The mains lead is not
correctly connected or
is damaged
No voltage in pump
circuit or mains supply
circuit
•
The pump does not pump water
CAUSES
REMEDIES
-
Make sure that the
supply is correctly
plugged in (plug,
extension lead, etc)
- Check the supply
cable
- Test or have tested
by an electrician
(circuit breaker, plug,
etc)
- Have tested by an
electrician or contact
the
service
department
- Contact the service
department to have
the motor replaced
REMEDIES
-
Replace the
condenser
REMEDIES
-
Check the mains
lead
- Check the pump
circuit and mains
supply circuit
REMEDIES
-
Holding the pump of
the outlet pipe remove
it from the water and
reimmerse it
23