Descargar Imprimir esta página

tau D750M Guía Para La Instalación página 17

Panel de mandos para dos motores monofásicos 230 vac

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Key:
N.C. =
Normally Closed
N.O. =
Normally Open
1 - 2
POWER input 230Vac, 50Hz, single-phase;
M2
transformer primary connector [1 blue wire (230V) + 1 red wire (V_SET) + 1 black
wire (0V)];
Tuning of the engines power
The red wire (V_SET) allow to select the output-voltage of the engines, consequently
their thrust-forces.
M5
transformer secondary connector [1 blue wire (0V) + 1 brown wire (15V) + 1 white
wire (24V) + 1 black wire (0V) + 1 red wire (12V)];
3 - 4
FLASHING LIGHT output 230Vac, 20W max. The signal is already modulated for
direct use. Flashing frequency increases slightly during closing;
5 - 6 - 7
MOTOR M1 power output (opens the leaf fitted with the electric lock), 230 Vac, max.
300 W. 5=CLOSE, 6=COMMON, 7=OPEN.
Note: connect the capacitor between terminals 5 and 7;
8 - 9 -10 MOTOR M2 power output, 230 Vac, max. 300 W. 8=CLOSE, 9=COMMON.,
10=OPEN.
Note: connect the capacitor between terminals 8 and 10;
11 - 12
OPEN/CLOSE button input (contact normally open); for operating information see dip
switch 2 function (COMMON=11);
11 - 13
N.O. PEDESTRIAN button contact input – commands total opening and closing of
motor 1 – governed by dip-switch 2 (COMMON=11);
11 - 14
STOP button input (normally closed contact); this stops the automatic system. At
the next command, the opposite operation to the previous one is performed (COM-
MON=9);
15 - 18
SENSITIVE EDGE input (fixed edge, dip 10 OFF) or 8,2 KΩ RESISTIVE SENSITIVE
EDGE (dip 10 ON), (normally closed contact);
Works only when the gate is opening; temporarily stops the gate and partially closes
it by about 20 cm in order to allow the obstacle to be removed. (COMMON=18).
16 - 18
PHOTOCELL OR SAFETY DEVICE input INSIDE the gate (Normally Closed con-
tact); COMMON=18.
When these devices trigger during the opening phase, they temporarily stop the gate
until the obstacle has been removed; during the closing phase they stop the gate and
then totally open it again.
17 - 18
PHOTOCELL OR SAFETY DEVICE input OUTSIDE the gate (Normally Closed con-
tact); COMMON=18.
Then these devices trigger during the closing phase, they stop the gate and then
totally open it again.
NOTE
Because the control of the safety system is performed on the photocell's trans-
mitter, this must always be powered by terminals 25 – 27, therefore if this con-
TERMINAL BOARD CONNECTIONS
D750M
17

Publicidad

loading