nection is broken the control unit will not accept any opening command. To
eliminate the safety system control, position dip-switch 6 to OFF.
19 - 20
ELECTRIC LOCK power output 12 Vac max. 15 W;
21 - 22
2nd RADIO CHANNEL output; the output mode can be selected by Dip 7 - 8;
23 - 24
GATE OPEN WARNING LIGHT output; 24 V ac, max 3W; the light lights with the
same frequency as that of the flashing light for the entire opening and closing ma-
noeuvre and remains on if the gate is open and off when the gate has closed;
25 - 27
24 Vac external transmitting photocell power supply output for safety device control
(connect the external TX photocell only) max. of 2 photocell transmitters;
26 - 27
24Vac output, 10W for the power supply of photocells, external receivers, etc.
28 - 29
AERIAL input (EARTH=28, SIGNAL=29);
TRIMMER
R. ANTA
second motor delay adjustment.
T. LAV.
Work Time adjustment.
CH.AUTO
Automatic closing time adjustment.
RALLENT.
adjustment of delay time.
Software
version
(Opening)
1.00 ÷ 1.04
1.05 ÷ 1.06
2.07 ÷ 2.12
3.00 ÷ 3.01
3.02 ÷ 3.03
2 - 33 sec.*
3.04 ÷ 3.05
1,5 - 6 sec.*
* with Dip Switch 9 in ON, the threshold increases by 3 seconds.
N.B.:
turn the TRIMMER clockwise to increase adjustments; turn it anticlockwise
to decrease.
DECELERATION SETTING PROCEDURE
-
Set dip 4 to OFF (deceleration disabled);
-
move the leafs to the closing position;
-
use the trimmer T.LAV. to set the leaf "high speed travel" as required. Check the precise set-
ting by means of a test manoeuvre.
CAUTION: the leaf must not open completely, but has to stop on elapse of the time
previously set on trimmer T.LAV.
-
After returning the leafs to the closing position, enable decel. (dip 4 set to ON).
-
Use the trimmer RALL. to set a time sufficient to complete the opening manoeuvre. At the
end, check the precise setting by means of a test manoeuvre.
18
R. ANTA
R. ANTA
(Closing)
2 - 4 sec.
2 - 10 sec.
2 - 4 sec.
2 - 10 sec.
2 - 4 sec.
2 - 10 sec.
2 - 8 sec.
2 - 16 sec.
2 - 33 sec.
2 - 33 sec.
T.LAV.
5 - 40 sec.
5 - 60 sec.
5 - 60 sec.
5 - 120 sec.
5 - 120 sec.
5 - 120 sec.
D750M
LOGIC ADJUSTMENTS
RALLENT.
CH. AUTO
1/3 T.LAV.
2 - 120 sec.
1/3 T.LAV.
2 - 120 sec.
0 - 30 sec.
2 - 120 sec.
0 - 40 sec.
2 - 120 sec.
0 - 40 sec.
2 - 120 sec.
0 - 40 sec.
2 - 120 sec.