MAINTENANCE
Regular maintenance allows the insert to function correctly
Before performing any maintenance, disconnect the appliance from the electrical supply

DAILY CLEANING

Clean using a vacuum cleaner and with the insert cold; the whole procedure will take just a few minutes a day.
- Vacuum the hatch, the fire surface, and the compartment around the combustion chamber where the ash falls.
- Remove the combustion chamber and use the metal spatula supplied to scrape off any waste. Clean out any blocked holes on both
sides.
- Vacuum the combustion chamber, clean the contacts between the chamber and its housing, replace the combustion chamber.
- Clean the glass, if necessary (when cold).
Do not vacuum up hot ash as this will damage the vacuum cleaner

WEEKLY CLEANING

Pellinsert 54 is equipped with two inspection hatches on the fire surface 'A', and two on the hearth cover 'B' to allow you to clean the
smoke duct easily and efficiently. This is fundamental maintenance.
"B"
"A"
- empty the tank and vacuum the base when the boiler is inactive and in any case once every 15 days.
SEASONAL CLEANING
(by Dealer)
After consumption of 2500 kg of pellets, the wording 'maintenance' will appear, entailing the following:
- Clean generally inside and out
- Clean/ exchange pipe carefully
- Clean and remove dirt from combustion chamber and relative compartment carefully
- Clean fans, check clearance and fixing mechanics
- Clean smoke channel (replace seals on smoke exhaust pipe as required)
- Clean smoke extraction fan compartment, flow sensor and thermo coupling control.
- Clean, inspect and scrape residues from the ignition resistance compartment, replace if necessary
- Visual inspection of electrical wires, connections and power lead
- Clean pellet tank and check clearance of cochlea-gear motor assembly
- Replace hatch seal if required
- Test function, cochlea load, ignition and function for 10 minutes, then shutdown.
If the insert is used very frequently, the smoke duct should be cleaned once every 3 months.
FAILURE TO PERFORM SEASONAL MAINTENANCE WILL FORFEIT THE WARRANTY.
32