Maintenance; Maintenance Schedule T-Line Dust Extractor; To Clean The Dust Extractor - Husqvarna T 7500 Manual De Usuario

Ocultar thumbs Ver también para T 7500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Introduction
WARNING: Use personal safety equipment,
Personal protective equipment on
refer to
page 5 , during service. Dust can be exposed
during maintenance and service.
WARNING: Most accidents involving
machines occur during trouble shooting,
service and maintenance as staff have to
locate themselves within the risk area of the
machine. Prevent accidents by being alert
and by planning and preparing the work.
WARNING: The motor should be switched
off during operations described in this
chapter unless otherwise stated.

Maintenance

Look for signs of wear,
damage or loose con-
nections of the controls
before the unit is con-
nected.
Do a check that the
Longopac is correct.
Do a check of the filter
cleaning mechanism.
Do a check of the
wheels. Look for dam-
age and bad connec-
tions.
Clean the pre-filter.
Replace the pre-filter.
Replace the Hepa filter

To clean the dust extractor

It is important to clean the dust extractor to prevent
circulation of dangerous dust. Always clean the dust
extractor before it is moved from the work area.
WARNING: Turn the motor switch to its OFF
position and disconnect the cord from the
wall outlet before you clean or do
maintenance to the product.
All equipment once used must be regarded as
contaminated and be treated thereafter.
877 - 004 - 07.01.2020
Maintenance
Before each
Daily
use
X
X
X
WARNING: All checks involving electric
components should only be performed by a
licensed electrician.
Maintenance schedule T-Line Dust
Extractor
The maintenance intervals are calculated from daily use
of the product. The intervals change if the product is not
used daily.
Weekly
When suc-
tion is low
X
X
X
X
All parts that are contaminated after service work
must be disposed in a correct procedure in plastic
bags. Refer to local regulations.
Use correct personal equipment when you clean the
product. Refer to
page 5 .
Clean the external surface with a moist cloth.
Clean the filters and the dust extractor in applicable
area.
Vacuum the pre-filter from the inside. Always use
dust extractors with Hepa filter and a soft brush to
not damage the filter.
Do not use water on electrical components.
6 months or
12 months or
1000h
2000h
X
X
Personal protective equipment on
7

Publicidad

Tabla de contenido
loading

Tabla de contenido