Ingersoll Rand ARO Manual Del Usuario página 24

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
2. Running the pump
On the home screen, select "Run Modes". The Run Modes Selection screen is displayed.
a. Batch Mode
On the Run Modes Selection screen, select "Batch". The Batch selection screen is displayed.
Each pump can be programmed to perform up to two independent batch sequences, named A and B.
Select the desired batch program to execute, press ENTER.
The batch start screen displays.
This screen displays the pre-programmed total volume and flow rate for the selected batch sequence. In this
screen, the values are read only. To change them they have to programmed in through the password-protected
setup sequence (see section 1.b.i).
To start the batch sequence, select "Begin Run" and press ENTER, or press the START button.
To exit this screen without starting the pump press either "NAVIGATE TO PREVIOUS" or "NAVIGATE TO HOME".
Alternatively, the batch sequence can be started using the external batch start buttons.
Note: Each pump can have up to two external batch start buttons, one for each of the two batch sequences
available (see blocks 6 or 7 in the installation section).
If the batch sequence for the particular external batch button that is selected is not programmed, the pump will
not start, but an error message will not be displayed.
While the pump is running the screen displays a percentage of the progress achieved to complete the batch
sequence.
Notice: The pump status has changed to "Running".
While the pump is running the batch program, it is possible to pause the pump momentarily without losing tally
of the amount dispensed. To pause the pump, press the START/PAUSE button.
When the STOP button is pressed, the pump will stop and the batch program is reset.
When the batch sequence is complete the screen will display a message.
To run the batch sequence again, select "Repeat Batch" and then press ENTER.
To exit, press either "NAVIGATE TO PREVIOUS" or "NAVIGATE TO HOME".
b. Proportional Mode
On the Run Modes Selection screen, select "Proportional" . The Proportional mode start screen is displayed.
To start the pump select "Begin Run" and press ENTER, or START/PAUSE button.
To exit this screen without starting the pump press either "NAVIGATE TO PREVIOUS" or "NAVIGATE TO HOME".
While the pump is running, the screen displays the input signal value and its calculated equivalent actual flow
rate.
Notice: The pump status has changed to "Running".
EN-7
47520296001_edD

Publicidad

Tabla de contenido
loading

Tabla de contenido