Dea NET24N Instrucciones De Uso Y Advertencias página 32

Cuadro de maniobra programable
Ocultar thumbs Ver también para NET24N:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
3.2 Unlocking access to programming
1. Scroll through the parameters with the buttons
and
until the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
to indicate that the control board
is waiting for the transmission of the unlocking
code;
4. Within 10 sec. press the CH1 of the "TX Mas-
ter", the display shows
returning to the list of parameters;
5. Access to programming is unlocked.
3.3 Unlocking access to programming and global reset
WARNING!
This procedure involves the loss of all
stored settings.
The procedure allows the unlocking of the control panel without
having to know its unlocking code.
Following this release, you must program the control panel
again and adjust all operating parameters, in particular, re-
member to properly set the configuration of parame-
ters (P028 - P029 - P030 – operator configuration). You
will also need to repeat the measurement of impact forces to
ensure the installation compliance to standards.
1. Scroll through the parameters with the buttons
until the display shows P008;
2. Access the parameter by pressing the button
3. The display shows alternately the writing
4. Press the button
;
5. Press the button again and hold for 5 seconds (releasing it
before, the procedure is terminated): The display shows the
fixed writing
list of parameters;
6. Access to programming is unlocked.
4
Inputs configuration
Where the installation requires different commands and / or additional to
the standard ones described by plan, you can configure each input for the
operation desired (eg START, PHOTOS, STOP , etc ...).
1. Scroll down the parameters with the
ing to the desired one:
● P017=for INPUT 1;
● P018=for INPUT 2;
● P019=for INPUT 3;
● P020=for INPUT 4;
● P021=for INPUT 5;
● P022=for INPUT 6;
2. Confirm by pressing on the
P018);
3. Scroll down with the
the desired operation (refer to table "Input Configuration parameters"
on page 31);
4. Confirm by pressing on the
5. Execute the new connection to the input just reconfigured.
5
Programming complete
WARNING At the end of the programming procedure, use the buttons
operator is now ready again for new manoeuvres.
30
;
before
;
, the display shows the flashing writing
followed by
, before returning to the
and
to see that correspond-
key to get access to the parameter (eg.
and
, keys to set the value corresponding to
key (display shows again P018).
and
;
and
until the appearance of the symbol "----", the

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido