Self-Learning Operating Times; Power Regulation - DIMOEL moov-b400 Manual De Instrucciones

Ocultar thumbs Ver también para moov-b400:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

It allows the leafs to always reach the closing position in the correct
order if its necessary.
Micro-switch 2, Invert. If ON, the motors push a second in the
closing direction before start opening.
It is only useful if an electric lock (not included in the kit) is installed.
Micro-switch 3, set to ON for single motor operation. Single-leaf
doors.
Micro-switch 4, automatic close. If ON, the door closes
automaticaly after the time programmed in switches 5 and 6.
Micro-switches 5 and 6, automatic close time.
Micro-switch 5
Micro-switch 6
Time (seconds)

6.2 Self-learning operating times:

The control board memorizes automatically all the gate
displacements and programmes automatically leaf's slowdown in
proximity of the limits switches after 2 complete manoeuvres.

6.3 Power regulation

In the circuit there are two rotary adjustment knobs VR1 and VR2.
They are used to adjust the maximum force of thrust level that will
make each one of the motors.
This is the maximum motor force during the distance.
The maximum force is used to terminate the opening and closing
limits, when door stops are reached.
If maximum force is exceded far from the stops it is interpreted as an
obstacle. In this case if the door is opening it stops, if it is closing it
reverses the movement and opens.
Turning to the right increases the force. Turning to the left is
reduced.
If set too low, it is possible the obstacle detector to make erroneous
detections, due the door inertia.
12
OFF
OFF
ON
OFF
ON
OFF
0
5
10
ON
ON
60