2 Turn the key ignition to ON position.
3 Press the RESTART RECEIVER button on the control panel.
4 Point the remote at the generator to favor the signal reception. It is
recommended that the cable of antenna in panel is also ready in an optimal
position to receive the signal.
5 Hold the START UP button for 2 or 3 seconds, the PILOT LAMP of the
generator panel blinks and the startup process begins. If it does not start at the
first attempt, other attempts will automatically follow to a maximum of 6.
STOP BUTTOM
START UP BUTTOM
LIGHT OF CONTROLLER
After the generator starts up it does not produce electricity immediately. The
generator will begin delivering after 20 seconds from the start up in order to ensure
that the engine is started without connected loads.
If the command does not work check point 10.6 to restore the system and 10.5 to
synchronize the startup controllers.
If the control light blinks or does not light your battery needs to be replaced
NOTE: Unless it is an emergency never interrupt, in any way, the start up
process. If the generator started mistakenly let maneuvers in process finish before
giving a new order with the control.
83