2 Keep pressing RESET button, while we push it, the PILOT LAMP pass to OFF-
ON-OFF process, then release RESET button.
3 Turn the key to OFF and synchronize the controls according to point 10.5
11. Maintenance:
The purpose of the maintenance program is to keep the equipment in good
working conditions and to achieve the maximum service life of it.
DANGER: Stop the engine before performing any maintenance.
If you need to start up the engine for any type of check, make sure that the area is
well ventilated. Exhaust gases contain poisonous carbon monoxide.
NOTE: Use original GENERGY spare parts or proven quality components for
maintenance.
Maintenance scheduling.
SERVICE
Engine oil
Air filter
Spark plug
Clean the sediment deposits of the
gasoline valve
Engine valves*
Combustion chamber*
Fuel tank*
Fuel hose*
NOTE: Perform maintenance more frequently when the equipment is used in
places with a lot of dust or very high temperatures.
NOTE: Services marked with an asterisk have to be performed by a
GENERGY service or qualified service center. Keep a receipt of the operations
carried out by the service center.
NOTE: Lack of compliance with maintenance services will shorten the life of
the generator and produce malfunctions that will not be covered by the warranty.
Warranty will not be respected if the detailed maintenance plan is not observed,
except in case of authorization to skip a service by GENERGY or an authorized
GENERGY service.
MAINTENANCE PERIODS
Check the level before each use. First oil change after 20 hours of
break-in. Subsequent oil changes every 100 hours of use.
Check and clean every 50 hours. Replace when it begins to wear out.
Clean and adjust the electrode every 50 hours Replace if any damage
is noticed in the porcelain or electrode, or if a proper flash is not
produced.
Clean every 300 hours or 1 year (whichever is first)
Adjust every 500 hours*
Clean every 500 hours*
Clean every 500 hours*
Replace every two years or sooner if any wear is noticed*