Clean spatter and scale from the shield cup and the tip as soon as possible. Spraying or dipping
the shieldcup in anti-spatter compound will minimize the amount of scale which adheres to it.
WARNING
Disconnect primary power at the source and wait that the torch has cooled before disassembling the
torch or torch leads. Frequently review the Important Safety Precautions at the front of this Manual.
Be sure the operator is equipped with proper gloves, clothing, eye and ear protection. Make sure no
part of the operator's body comes into contact with the work piece while the torch is activated.
CAUTION
Sparks from the cutting process can cause damage to coated, painted, and other surfaces such as
glass, plastic and metal.
NOTE Handle torch leads with care and protect them from damage.
TORCH CONSUMABLE PARTS SELECTION
To change the torch consumable parts use the following procedure: Position the torch with the shield
cup facing upward to prevent these parts from falling out when the cup is removed.
WARNING: Wait the torch has suffi ciently cooled before replacing torch parts.
1. Unscrew and remove the shield cup from the Torch Head Assembly.
2. Remove the tip, gas distributor, and electrode.
3. Install the electrode, gas distributor, and tip.
4. Hand tighten the shield cup until it is seated on the torch head. If resistance is felt when installing
the cup, check the threads before proceeding.
10
WORK TABLE