DISPLAY
OFF
START
PELLET FEEDING
IGNITION
BURNING
OPERANT
MODULATION
BURN POT CLEANING
FINAL CLEANING
STAND BY
STAND BY EXT
COOLING STAND BY
COOL. STDBY
BLACK OUT
LOW
HOT
SERVICE
REASON
Stove o
The start-up phase is in progress
The feeding of the pellet during the ignition phase is in progress
The ignition phase is in progress
The start-up phase is in progress
The normal work phase is in progress
The stove is modulating
The automatic burn pot cleaning is in
progress.
When the stove is switched-o , nal cleaning is in progress. The nal cleaning phase lasts about 10
minutes.
Stove o due to temperature reached
and in stand-by for re-ignition.
Stove o due to an external
thermostat, waiting for re-ignition
A new ignition is attempted when
the stove has just been switched-o
The stove is cooling due to black out
Room thermostat set at minimum
value.
Set room thermostat set at maximum
value.
When this message appears, contact the authorised technician for ordinary cleaning of the appliance.
If cleaning is not performed, the message will be displayed at every ignition but without interrupting
normal stove operation.
DISPLAYS
The automatic burn pot cleaning (not in 1st power) is performed
at pre-established intervals of continued working.
To deactivate the STAND-BY function see the speci c chapter.
To deactivate the STAND-BY function see the speci c chapter.
When the stove switches o , it is necessary to wait for the
complete shutdown of the fumes motor before cleaning the burn
pot.
The stove can only be re-ignited when these operations have
been performed.
On completion of the cooling phase, it will re-ignite automatically.
In this way the stove only works at 1st power independently
from the power set. To exit this function just raise the room
temperature using button 4 and then key 2.
The stove works at set start, without ever modulating. To escape
this function just lower the set temperature using key 4 and then
key 1.
ENGLISH
SOLUTION
-
-
-
-
-
-
63