PROGRAMMING AND STARTUP
Programme opening
1
3
Programme closing
1
3
Finish the programming mode
1 Place P3 in "OFF".
The open/close runs both on opening and
closing will be stored.
50
Installation Manual
2
G184E
4
G184G
2
G184I
4
G184K
1 Start opening: press ST1; the door begins to open
at slow speed.
2 Start fast speed on opening: press ST1 at the
point chosen for the start of fast speed.
3 Start soft-stop in opening: press ST1 at the point
chosen for the start of slowdown.
G184F
If this step is not carried out, the door will not
carry out soft-stop in opening.
4 Finish opening: the door stops automatically when
reaching the opening limit switch (FCA).
G184H
1 Start closing: press ST1; the door begins to close at
slow speed.
2 Start fast speed in closing: press ST1 at the point
chosen for the start of fast speed.
3 Start soft-stop in closing: press ST1 at the point
chosen for the start of soft-stop.
G184J
If this step is not carried out, the door will not
carry out soft-stop in closing.
4 Finish closing: the door stops automatically when
reaching the closing limit switch (FCC).
Photocell shadow function: when the photocell
shadow function is activated, the photocell is
G184L
disabled in the last part of the closing run. To do
this, the control panel detects the position in which
the leaf activates the photocell whilst programming
the closing run, and takes it as a reference for
disabling during operations (disabling comes about
a moment before the point detected during
programming).
The positions in which the leaf begins to speed
up and slow down, both on opening and in
closing, will also be stored.