Operating the generator
Display message
Description
OIL TEMP PRESS
Engine temperature too
high.
GENERATOR ALERT!
General alarm message
OVERLOAD!
The consumers generate an
overload at the output.
SHORT CIRCUIT
The consumers cause a short
circuit at the output.
OVER TEMPERATURE
Overheating
LOW POWER ENGINE
The inverter supply voltage
has dropped.
RESTART GEN?
Message appears after the
generator has stopped due
to overheating.
20
Generator behaviour
The generator stops.
The generator stops.
The inverter switches off,
therefore no voltage is
supplied but the engine
carries on running until it
goes off.
The inverter switches off,
therefore no voltage is sup-
plied but the engine carries
on running until it goes off.
The inverter switches off so
no voltage is supplied to
cool the generator, but the
engine carries on running.
The generator stops.
The generator is switched
off.
TEC30EV
Measures
Switch off the generator and
leave it to cool down. Check
that the ventilation openings
are not obstructed.
If the problem persists,
contact the manufacturer's
branch office in your country
(addresses on the manual's
back page).
Check the system by refer-
ring to the troubleshooting
table (page 27).
If the problem persists,
contact the manufacturer's
branch office in your country
(addresses on the manual's
back page).
Reduce the connected load.
Stop the generator and
restart it.
Check the connected
consumers. Stop the
generator and restart it.
Leave the engine to cool
down for a few minutes. Stop
the generator and restart it.
Reduce the connected load
and start the generator
again.
Press the start button to
restart the generator.
EN