TEC30EV
11
Troubleshooting
Fault
Cause
The remote
Starter battery is flat.
control does not
Main fuse is blown.
come on when
the on/off switch
Power cable is disconnected or the
is pressed.
plug is removed.
The starter does
Starter battery is flat.
not work when
The main switch is at "0".
the start button is
pressed.
Inverter is damaged.
Power cable is disconnected or the
plug is removed.
Starter motor does not start.
The starter turns
Fuel level too low.
but the
Inverter is damaged.
generator does
not start.
Power cable is disconnected or the
plug is removed.
Injectors are dirty or faulty.
Engine malfunction.
The generator
Too much oil in the engine.
tends to go off.
Load is over 2.5 kW.
Air filter is dirty.
Inverter is damaged.
Malfunction in the pump power
supply.
Injectors are dirty or faulty.
The generator is
Inverter is damaged.
running but does
Power cable is disconnected or
not supply any
defective.
voltage.
EN
Troubleshooting
Remedy
➤ Charge the starter battery.
➤ Replace the main fuse.
➤ Contact an authorised
workshop.
➤ Charge the starter battery.
➤ Set the main switch to "1".
➤ Contact an authorised
workshop.
➤ Fill up with fuel.
➤ Contact an authorised
workshop.
➤ Drain the oil.
➤ Reduce the consumers.
➤ Clean the air filter (chapter
"Servicing the air filter" on
page 25).
➤ Contact an authorised
workshop.
➤ Contact an authorised
workshop.
27