Siemens SIMOTICS M-1PH818 Instrucciones De Servicio página 184

Motor síncrono
Ocultar thumbs Ver también para SIMOTICS M-1PH818:
Tabla de contenido

Publicidad

Assembly instructions ECblue
Diagram for setting via external signal.
nM Motor speed
100 % Rated speed
Si Speed setting signal 0...10 V / 0...100 % PWM
Possibilities for speed setting
GND
10V GND
Signal PWM
f = 1...10 kHz
184
L-BAL-F065-GB 1617 Index 004
nM
100 %
90
80
70
60
50
40
30
20
10
0
1
2
3
0
10
20
30
Control via external setting signal
E1
By external wiring with a resistor (499 Ω / 0,25 W) between the terminals
and
possible.
+
0...10 V
E1
Speed setting by 10 kΩ potentiometer at terminals
off at terminals
10 k
10V GND E1
10 k
Control via external setting signal PWM.
-
+
15...28 V
Part.-No. 00702801-GB
n-min = 50 %
n-max. = 100 %
4
5
6
7
8
9
40
50
60
70
80
90 100 0...100 % PWM
"GND"
parallel to the input signal, activation with a
"E1"
.
18/28
Electrical installation
Analog In 1
0...10 V
10
28.04.2015
v_ecblue_100_set_min50_max100.vsd
0...10 V
.
0...20 mA
"+10 V"
"E1"
signal is
"GND"
and
pick-

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Simotics m-1ph822

Tabla de contenido