DMX Channel Modes, Assignments, and Values
10-Channel
Channel
·
·
·
Scorpion™ Dual User Manual Rev. 1
Function
1
Control Functions
2
Strobe
3
Pattern Selection
4
Zoom
5
Y-Axis Rolling
6
X-Axis Rolling
7
Z-Axis Rolling
8
Pan
9
Tilt
10
Scan Speed
For manual operation of lasers using DMX control, be sure Channel 1 is set to
DMX mode (000—085).
For automatic operation of lasers using DMX control, be sure Channel 1 is set to
Auto program (086–170).
Channel 2 must be set to 010–255 for Channel 1 to be operational.
Value
Setting
000 ó 085
DMX mode (other channels activated)
086 ó 170
Auto program
171 ó 255
Sound-Active
000 ó 009
No function
010 ó 249
Slow to fast
250 ó 255
On
000 ó 255 Patterns as shown in
000 ó 127
100%–5%
128 ó 169
Zoom in
170 ó 209
Zoom out
210 ó 255
Zoom in and out
000 ó 127
Fixed position on y-axis (0 to 359°)
128 ó 191
Clockwise rolling, slow to fast
192 ó 255
Counter-clockwise rolling, slow to fast
000 ó 127
Fixed position on x-axis (0 to 359°)
128 ó 191
Clockwise rolling, slow to fast
192 ó 255
Counter-clockwise rolling, slow to fast
000 ó 127
Fixed position on z-axis (0 to 359°)
128 ó 191
Clockwise rolling, slow to fast
192 ó 255
Counter-clockwise rolling, slow to fast
000 ó 127
Fixed position (128 horizontal points)
128 ó 191
Clockwise movement, slow to fast
192 ó 255
Counter-clockwise movement, slow to fast
000 ó 127
Fixed position (128 vertical points)
128 ó 191
Clockwise movement, slow to fast
192 ó 255
Counter-clockwise movement, slow to fast
000 ó 127
Fast to slow (manual)
128 ó 169
Slow to fast (automatic)
170 ó 209
Fast to slow (automatic)
210 ó 255
Fast to slow, then slow to fast (automatic repeat)
Patterns
table.