DISPLAY
FUMES FAILURE
FUMES PROBE
FUMES
OVERTEMP AL.
CLEAN CHECK UP 1 2
1 = IN BURNING PHASE
2 = IN OPERANT PHASE
DEPRESSION
ALARM
NO
IGNITION
BLACK OUT NO IGN.
NO PELLET
COOLING STAND BY
DAMAGE DEPR
SENSOR
COMMAND AUGER
ALARM
EXPLANATION
Indicates the presence of an alarm.
Fault related to the ue gas exhaust
motor.
Fault related to the fumes probe.
The ue gas temperature has
exceeded 310°C
The combustion chamber or burn pot
bottom are dirty.
The door is not closed correctly.
The ash pan is not closed correctly.
The depression sensor is faulty.
The ue exhaust pipe is blocked.
Incorrect installation
The mechanical depression sensor
has tripped
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
No power during the ignition phase.
In the work phase, the t° of the ue
gases has dropped below factory
parameters
Attempt to release the alarm with
stove still in cooling mode.
Component disconnected or faulty
Abnormal functioning
of pellet feeding
ALARMS
On: indicates the presence of an alarm
O : indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
The restoration operations must be carried out by an authorised
technician.
The restoration operations must be carried out by an authorised
technician.
Check the pellet ow (see "Pellet feed adjustment").
Check that the machine is clean, including the fumes route.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an authorised
technician.
Make sure the holes at the burn pot bottom are completely free.
Check cleanliness of the fumes pipe and the combustion chamber.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Other restoration operations must be carried out by an authorised
technician.
Contact after-sales centre
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
Switch the stove to OFF using key 1 and repeat the procedure
described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
Check for the presence of pellets in the feed-box.
Regulate the pellet ow.
Other restoration operations must be carried out by an authorised
technician.
Every time the stove displays one of the alarms listed above it will
switch-o automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and STAND BY alternately on the display.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
Contact after-sales assistance
Contact after-sales assistance
ENGLISH
SOLUTION