Code
Description
Internal error: Real Time Clock
753
module is in emergency mode
754–
Provides information about the
755
internal processor status
757
Hardware error in the Real
Time Clock module
758
Internal error: Real Time Clock
module is in emergency mode
760
Internal hardware error
761–
Provides information about the
765
internal processor status
Emergency power limiter has
766
been activated (max. 750 W)
Provides information about the
767
internal processor status
Power limit different in the
768
hardware modules
772
Memory unit unavailable
Software update group 0 (in-
773
valid country setup)
PMC power stage set unavail-
775
able
776
Invalid device type
781–
Provides information about the
794
internal processor status
*) If status code persists: Contact a Fronius-trained service technician
Class 10–12 Sta-
1000–1299 – Gives information regarding the internal processor program status
tus Codes
Description

Customer Service

IMPORTANT! Please contact your Fronius dealer or a Fronius-trained service technician if
-
-
Operation in
When operating the inverter in extremely dusty environments:
dusty environ-
when necessary, clean the cooling elements and fan on the back of the inverter and the
ments
supply air openings in the mounting bracket using clean compressed air.
58
Behavior
inaccurate time, time loss
possible (grid power feed
operation normal)
Warning message on the
display
Error message on the dis-
play; the inverter does not
feed current into the grid
inaccurate time, time loss
possible (grid power feed
operation normal)
Error message on display
Warning message on the
display
Error message on display
Warning message on the
display
Warning message on the
display
Warning message on the
display
This is of no concern if the inverter is functioning without prob-
lems and it appears only in the "PS Status" setup parameter. In
the event of an actual fault, this status code supports Fronius
Technical Support in the failure analysis.
an error appears frequently or for a long period of time
an error appears that is not listed in the tables
Remedy
Reset the time and date on the in-
verter
*)
*)
Reset the time and date on the in-
verter
*)
*)
*)
Press the '"Enter" key to confirm
the error; *)
*)