Safety cut-out
Cause:
(continued)
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Technical data
Multi Charger 04 /
Mains voltage U
06
Mains voltage tolerance
Mains frequency
Max. open circuit power consumption per charging circuit
Nominal output P
MC 04 (U
MC 06 (U
Max. nominal output per charging circuit at U
Charging voltage [V DC] per charging circuit (vehicle voltage) U
Arithmetic charging current [A DC] at 230 V per charging circuit I
R.M.S. current [Aeff. DC] * 66per charging circuit
Battery capacity per charging circuit
Chargeable cells per charging circuit
On-time
Charging characteristic
Protection
Time until safety cut-out per charging circuit
Operating temperature **
Transport and storage temperature
Weight
MC 04
MC 06
Dimensions w x h x d
MC 04
MC 06
* R.M.S. current corresponds to the specifications for conventional battery chargers
** The charger's technical data assume that the ambient temperature will not normally
The proper functioning of the charger is tested at 5-85% humidity
Component specification: Climate class B
Active accessories using too much power
Switch off accessories and restart charging
Faulty battery (e.g. cell short circuit, smell of gas, differing cell temperatu-
res, housing deformation, different liquid levels or liquid leaking, etc.)
Have battery checked. On no account allow charging to continue
Incorrect charger type for this application
Have battery and multicharger checked and ensure they are compatible
[V AC]
1
depends on U
1
V AC 100 - 240 V)
1
V AC 100 - 240 V)
1
exceed 25°C, but may occasionally reach 35°C. If the ambient temperature is excee
ded, decreased output power and/or temporary malfunction may result.
1
230 V
1
418 x 288 x 98 mm (16.5 x 11.3 x 3.9)
584 x 288 x 98 mm (23.0 x 11.3 x 3.9)
6
100 - 240 V
+/-15 %
50/60 Hz
1.5 W
135 - 235 W
200 - 350 W
48 W
12 V
2
4.0 A
2
6.0 A
3 -110 Ah
100 %
IUoU
IP30
55 h
-10°C to +60°C
14°F to 140°F
-20°C to +80°C
4°F to 176°F
5770 g (12.72 lb.)
7060 g (15.56 lb.)
6