Bourgeat SATELLITE 4G Instrucciones De Uso Y Mantenimiento página 33

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Check the power source for the trolley, ensure that the fan is not blocked and that the sensor behind the air circuit is clear and clean.
If the «spanner + hand» pictogram appears, the safety thermostat has been triggered, the trolley is in fault. Contact your installer.
- The following pictograms appear :
Press the screen once
An adjustment problem is detected. Check that the temperature sensor behind the air circuit is clean and clear. Confirm the error message.
If the «spanner + hand» pictogram appears, the trolley is in fault. Contact your installer.
- Humidification is not sufficient :
The spray nozzle is clogged :
* Dismount the air circuit manually by pulling it upwards then towards you once it has shifted
* Remove the nozzle manually from the tube (1) via the large yellow nut (5).
* Check that the screen (2) and the seals (6) are in good condition.
* Dismount the jet orifice (3) of the head of the nozzle (4) using a flat-head screwdriver
* Soak the orifice (3) + nozzle (4) unit in a descaling solution or vinegar, let stand for 8h.
* Check that the hole of the orifice (3) is not clogged.
* Remount the unit.
For any other breakdown, contact your installer.
y On cold trolleys that are operating :
- The following pictogram appears :
The trolley door is open, check that the latter is properly closed.
OK
OK
________________
OK
OK
OK
OK
- 33 -

Publicidad

Tabla de contenido
loading