Do not smoke during the below work. Do no work in
the vicinity of sparks, flames or open fire.
Regularly clean the ventilation slots.
Changing the oil (fig. A & C)
The oil must be changed after the first 20 operating hours,
and then after every 100 hours or 6 months.
Remove the cover (11).
I
Place a receiving bin under the bleeding point.
I
Remove the dipstick (6) from the filling-point.
I
Remove the screw (12) from the bleeding-point.
I
Tilt the machine slightly forwards to remove all oil.
I
Re-insert the screw (12) and tighten it securely.
I
Fill the crankcase with the prescribed amount of oil.
I
Replace the dipstick.
I
Replace the cover.
I
Checking the oil level (fig. A)
Check the oil level before starting the motor.
Remove the dipstick (6) from the filling-point.
I
Clean the dipstick.
I
Insert the dipstick into the filling hole for a few seconds before
I
pulling it out again.
Check the oil-level. The oil level should be at a rate between
I
full and empty.
If the level is below this mark, refill the oil.
I
Cleaning the air filter (fig. D)
The air filter should be cleaned after every 50 operating hours.
Remove the screws (13).
I
Lift the side (14) from the machine.
I
Remove the screws (15) and the bracket (16).
I
Remove the air filter (17) from the holder.
I
Clean the air filter with spirits or ethanol.
I
Pinch the air filter out. Do not twist!
I
Immerse the filter in clean motor oil.
I
Pinch the filter out and mount it into place.
I
Replace the side using the screws.
I
Cleaning the fuel filter (fig. E)
Remove the lid (4) from the filler opening.
I
Lift the fuel filter (18) from the filler opening.
I
Clean the filter with spirits or ethanol.
I
Dry the filter with a soft cloth.
I
Replace the filter in the filler opening.
I
Place the lid back on the filler opening.
I
Checking the spark plug (fig. F & G)
Remove the cover (19).
I
Remove the spark plug cable (20) from the spark plug.
I
Remove the spark plug (21) using the spark plug spanner.
I
Clean the electrode (22) using a steel brush.
I
Check the contact distance (correct value 0.7 - 0.8 mm) and
I
adjust as necessary.
Replace the spark plug.
I
Replace the cover.
I
TROUBLE-SHOOTING
If the machine is not working properly, take the following steps
to correct the problem. If you cannot correct it yourself,
contact your dealer.
31L809
Engine does not start
I
Check if the fuel tap is open.
I
Check if there is fuel in the tank.
I
Check that the on/off switch is in the "ON" position.
I
Pull harder on the start cord.
I
Check if the spark plug is properly placed.
I
Check if the spark plug cable is on the spark plug.
I
Clean the spark plug and check the contact distance.
Motor runs irregularly
I
Check if the spark plug is properly placed.
I
Check if the spark plug cable is on the spark plug.
I
Clean the spark plug and check the contact distance.
I
Check if the right fuel has been used.
Generator supplies no energy
If the indicator lamp (2) is not on, there is a defect that you cannot correct yourself.
Contact your dealer.
If the indicator lamp is on:
I
Press the reset button belonging to the output used.
I
Check the wiring.
I
Check if there has been a short circuit or an overload.

TRANSPORT AND STORAGE

If the machine is out of use for a longer period of time, the fuel
tank must be emptied and the oil must be changed.
Empty the fuel tank.
I
Change the oil.
I
Cover the machine and place it in a clean an dry environment.
I

TECHNICAL DATA

Speed
Output voltage
Max. output voltage
Max. output capacity
Output frequency
Max. fuel consumption
Contents fuel tank
Crankcase capacity
Oil
Spark plug type
Weight
Level of sound pressure:
L
(sound pressure)
pA
L
(acoustic power)
WA
Take appropriate measures for the protection of
hearing.
GUARANTEE
Refer to the enclosed guarantee conditions for the terms and
conditions of guarantee.
ENVIRONMENT
Should your machine need replacement after extended use,
do not put it in the domestic waste but dispose of it in an
environmentally safe way.
31L809
min
-1
3,000
V
230
A
3.5
VA
800
Hz
50
l/h
0.59
l
4.5
l
0.4
SAE 10W/40
NGK BPR-4ES
kg
30
31L809
dB(A)
81
dB(A)
94
21