Cleaning the air filter (fig. A & C)
Clean the air filter every 50 operating hours.
Loosen the two clamping brackets (14).
Remove the lid (13).
Remove the air filter (15) from the filter holder (16).
Clean the filter with spirits or ethanol.
Pinch the filter out. Do not twist!
Immerse the filter in clean motor oil.
Pinch the filter out and mount it into place.
Re-fit the filter.
Re-fit the cover.
Cleaning the fuel filter (fig. D)
Remove the lid (5) from the filler opening.
Lift the fuel filter (17) from the filler opening.
Clean the filter with spirits or ethanol.
Dry the filter with a soft cloth.
Replace the filter in the filler opening.
Place the lid back on the filler opening.
Cleaning the filters in the fuel pipe
The filters in the petrol tap and the settler must be cleaned in time
in order to avoid obstruction.
Clean the filters with petrol.
Checking the spark plug (fig. E & F)
Remove the spark plug cable (18) from the spark plug.
Remove the spark plug (19) using the spark plug spanner.
Clean the electrode (20) using a steel brush.
Check the contact distance (correct value 0.7 -0.8 mm) and
adjust as necessary.
Replace the spark plug.
TROUBLE-SHOOTING
If the machine is not working properly, take the following steps to
correct the problem. If you cannot correct it yourself, contact your
dealer.
Engine does not start
Check if the fuel tap is open.
Check if there is fuel in the tank.
Check that the on/off switch is in the "ON" position.
Check the oil-level.
Pull harder on the start cord.
Check if the spark plug cable is on the spark plug.
Clean the spark plug and check the contact distance.
Motor runs irregularly
Check if the spark plug is properly placed.
Check if the spark plug cable is on the spark plug.
Clean the spark plug and check the contact distance.
Check if the right fuel has been used.
Generator supplies no energy
Check if there has been a short circuit or an overload.
Check that the reset switch is in the "ON" position.
Check the wiring.
TRANSPORT AND STORAGE
If the machine is out of use for a longer period of time, the fuel tank
must be emptied and the oil must be changed.
Empty the fuel tank.
Change the oil.
Cover the machine and place it in a clean an dry environment.
TECHNICAL DATA
Output voltage
O utput voltage
O utput capacity
P ^ max
Output frequency
Fuel consumption
Max. fuel consumption
Contents fuel tank
Crankcase capacity
Dimensions
Weight
Level of sound pressure:
L
(sound pressure)
pA
L
(acoustic power)
WA
Take appropriate measures for the protection of hearing.
GUARANTEE
Refer to the enclosed guarantee conditions for the terms and
conditions of guarantee.
ENVIRONMENT
Should your machine need replacement after extended
use, do not put it in the domestic waste but dispose of it in
an environmentally safe way.
DECLARATION OF CONFORMITY
Kinzo B.V. declares that the machines:
Generator 48P7400
have been designed in compliance with the following standards:
EN 55012, EN 55014-1, EN 61000-6, EN 122601
and in accordance with the following directives:
73/23/EEC, 89/336/EEC, 93/68/EEC, 97/68/EC, 98/37/EC,
2000/14/EC, 2002/88/EC
The EC type approval has been provided by:
TÜV Rheinland Product Safety GmbH, Am Grauen Stein,
Köln, Germany
Ede, The Netherlands, July 2005
Kinzo B.V., Postbus 735, 6710 BS Ede, The Netherlands
GB
48P7400
V 230
A 10.8
VA 2,000
kVA 2.3/5 min.
Hz 50
l 0.47
l/h 1.43
l 13.5
l 0.47
mm 600 x 430 x 445
kg 42.3
48P7400
dB(A) 75
dB(A) 95
M. Kinsbergen
Director
21