9.2 Resistencia térmica
4 veces la corriente nominal de forma continua.
20 veces la corriente nominal durante 10s.
80 veces la corriente nominal durante 1s.

9.3 Normativa

1. EMC requirements
- Emission
1.1. Radiated emission
1.2. Conducted emission
- Immunity
1.3. 1MHz damped oscillatory
waves
1.4. Electrostatic discharge
1.5. Radiated radiofrequency
electromagnetic fields
1.6. Electrical fast transients
1.7. Surge
www.fanox.com
IEC 60255-26
Radiated emission limit for Class A (group 1
for EN 55011) on Enclosure port. Frequency
range 30MHz - 230MHz (Quasi Peak
EN 55022
40dBμV/m). Frequency range 230MHz -
1000MHz (Quasi Peak 47dBμV/m)
EN 55011
IEC 60255-26
Conducted emission limit for Class A (group 1
for EN 55011) on Auxiliary power supply port.
Frequency range 0.15MHz – 0.5MHz (Quasi
EN 55022
Peak 79μV, Avg 66μV). Frequency range
0.5MHz – 30MHz (Quasi Peak 73μV, Avg
EN 55011
60μV)
IEC 60255-26
Class 3, Repetition frequency 400Hz,
Duration of each application 3s.
Common mode for all terminals ±2.5kV.
IEC 61000-4-18
Differential mode for all terminals excepts
Communication port ±1kV
IEC 60255-26
Level 4, Contact discharge ±8kV. Air
discharge ±15kV
IEC 61000-4-2
IEC 60255-26
Level 3, Test field strenght 10V/m, Frequency
80MHZ - 1000MHz and 1400MHz -
2000MHz, AM Modulation 80% for 1KHz
IEC 61000-4-3
carrier sinusoidal signal
IEC 60255-26
Level 4, Power supply to Earth terminals
±4kV, Signal and control terminals ±2kV.
Repetition frequency 5KHz, Burst duration
IEC 61000-4-4
75s.
IEC 60255-26
Level 4, Line to earth for all terminals ±4kV.
Line to Line for all terminals excepts
IEC 61000-4-5
Communication port ±2kV