9 Tap-On Foot Pedal Battery; Installation/Replacement; Foot Pedal Synchronization - Cavitron Prophy-Jet Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 55
To remove the air supply line from the Cavitron
Jet
System, turn off the dental office air supply.
®
Disconnect the air supply line from the dental office air
supply, then push on the outer ring of the system's air
inlet and gently pull out the air line. If a quick-disconnect
connector is attached to the end of the hose, relieve the
air pressure by pressing the tip of the connector and
allowing the air to escape.
7.9 Tap-On
Foot Pe
TM
Press ring to release
air supply tube.
7.9 Tap-On
Foot Pedal Battery
TM

Installation/Replacement

Turn Tap-On
Wireless Foot Pedal over and using a
TM
Philips screwdriver carefully remove battery cover screw
and battery cover. If applicable, remove used batteries
and install two new "AA" batteries as shown. Do not
depress Tap-On
Foot Pedal while installing batteries.
TM
The communication light will blink for approximately
two seconds to indicate the Tap-On
to communicate with the unit. If the light does not blink,
check the batteries. If the batteries are good and the
light doesn't blink, a communications error may exist.
To re-establish communication with Tap-On
review Synchronization procedure, section 7.10.
The remote frequency communication can be bypassed
using the auxillary Tap-On
Section 11.2 Technical Support and Repair for further
action.
Replace the battery cover and screw and hand tighten
cover with Philips screwdriver.
Remove batteries if Tap-On
for an extended period of time.
7.10 Tap-On

Foot Pedal Synchronization

TM
The Tap-On
Wireless Foot Pedal supplied with your
TM
system has been factory synchronized with the base unit.
Prophy-
®
Look for blinking
communications
light.
Foot Pedal's ability
TM
Foot Pedal
TM
Foot Pedal cable. Refer to
TM
Foot Pedal is to be stored
TM
Should a replacement Tap-On
synchronization will be required prior to system operation.
Perform the following steps to synchronize the Tap-On
Pedal with the base unit;
1. Turn the Main Power switch located at the center
front underside of the system to the OFF (O)
position.
2. Install a new set of "AA" batteries into the Foot
Pedal (See Section 7.9) Leave the battery cover
of the foot control open so the red push button is
accessible.
3. Maintain a distance of no more than 10 feet (3
meters) between the base unit and Tap-On
Pedal during the synchronization process.
4. Turn the Main Power switch to the ON (I) position
and wait for the Diagnostic Display graphics to light
(refer to Section 8.2).
5. While all graphics are lit, press the Purge button,
located on the Diagnostic Display. The graphics will
begin to blink in a sequential pattern, representing
the synchronization mode. This mode will last 5 to 6
seconds.
6. During this mode, press the red button located in
the battery compartment of the Tap-On
This will complete the synchronization process.
7. Synchronization is successful when all graphic lights
blink at the same time.
8. To verify proper communication, fully depress the
foot control to the second position.
9. Attach battery cover and tighten the screw.
10. In the event communication cannot be established,
temporarily use the supplied Auxillary Tap-On
Pedal Cable to connect the Tap-On
directly to the unit.
11
Foot Pedal be necessary,
TM
TM
TM
Foot
PURGE
TM
Foot Pedal.
TM
Foot
TM
Foot Pedal
Foot

Publicidad

Tabla de contenido
loading

Productos relacionados para Cavitron Prophy-Jet

Tabla de contenido