Rogue™ R1 Wash QRG
AC Power
Power Linking
AC Plug

Replacing The Fuse

DMX Linking

DMX Connection

This product has an auto-ranging power supply that can work with an input voltage
range of 100–240 VAC, 50/60 Hz.
You can link up to 10 Rogue™ R1 Wash products at 120 V, 18 products at 208 V,
or 21 products at 230 V. Never exceed this number. Power linking cords can be
purchased separately.
Connection
AC Live
AC Neutral
AC Ground
To eliminate unnecessary wear and improve its lifespan, during periods of
non-use completely disconnect the product from power via breaker or by
unplugging it.
1. Disconnect this product from power.
2. Using a flat head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
The Rogue™
R1
a 3- or 5-pin DMX serial connection. A DMX Primer is available from
www.chauvetprofessional.com.
The Rogue™ R1 Wash uses a 3- or 5-pin DMX data connection for its DMX
personalities: 14CH, 15CH, 19CH, and 21CH. See the User Manual for
information about connecting and configuring the product for DMX operation.
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Green/Yellow
Wash
will
work
3
Screw Color
Brown
Yellow/Brass
Blue
with
a DMX controller
EN
Silver
Green
using