Using the pyrolitic cycle:
1- Rotate the function selector to the position "
". On the display, appears the indication " ECO " or
" SUP ". The preset time is 90 min, this can be varied from 90 min (Eco mode) to 120 min (Sup mode) via
the programmer (setting button " + " or " - "). If the oven is very dirty, it is recommend o increase the time
to 120 min, if the oven is moderately dirty reduce the cleaning cycle time to 90 min.
2- It is possible to defer the start time of the pyroclean cycle by changing the END time via the
programmer.
3- After few minutes, when the oven reaches a high temperature, the door locks automatically. The
pyroclean cycle can be stopped at any time by turning the function selector back to '0' (the word OFF will
be displayed for 3 seconds).
4- Once the pyroclean cycle is finished, the pyrolysis will switch off automatically. On the display appears
the indication "END" until the door is locked then "0--n".
5- You can turn the function selector back to " 0 " but if the temperaure is still high, the "0--n " indication
appears to inform that the door is locked.
Use of the pyrolytic cycle in Touch Control ovens:
1- Rotate the function selector into position pyrolisys. The display will show either "ECO" or "SUP"
2- The pre-set time is 90 minutes but it can be varied from 90 min. (Eco mode) to 120 min. (Sup mode)
using the programmer (" +" or "-" key). If the oven is very dirty, the time should be increased to 120 min.,
while if the oven is only a slightly dirty, reduce the cleaning cycle to 90 min.
4.3 Maintenance
REMOVAL AND CLEANING OF THE SIDE RACKS
1. Unscrew the bolt in an anti-clockwise direction.
2. Remove the side racks by pulling them towards you.
3. Clean the side racks in a dishwasher or with a wet sponge and then dry them immediately.
4. Having cleaned the side racks, put them back in and reinsert the bolts, ensuring that they are fully
tightened.
A
REMOVAL OF THE OVEN WINDOW
1. Open the front window.
2. Open the clamps of the hinge housing on the right and left side of the front window by pushing them
downwards.
3. Replace the window by carrying out the procedure in reverse.
EN 12