Control Panel; Starting The Cleaner; Important; Use - IPC Atomax Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
USING
THE CLEANER

CONTROL PANEL

A - On/off switch
Indicator lights (if featured).
B - Power indicator light.
C - Fault indicator light.
D - Programmed maintenance
indicator light.

STARTING THE CLEANER

1) Turn on the water supply tap (fig. 4A).
2) Connect the water cleaner to the mains electricity supply via
the omnipolar switch or by plugging the plug into the socket.
3) Start the cleaner by turning the selector switch to pos. 1
(fig. 6A).
Warning
!
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
4) Press the trigger on the gun and begin washing.
!
Warning
In water cleaners with the "Total Stop" system, the motor starts
and stops when the lever on the lance handle is actioned or
released.
!
Danger
Do not block the handle lever in the delivery position.
!
Warning
If malfunctions are found at startup, refer to the chapter "Trouble
Shooting".
SIGNALS AND FAULTS DISPLAYED.
Indicator light B): Power is on when the indicator light is on
steady (switch "A" in pos. I); when the indicator light is flashing,
the high pressure washer is in "TSI" status.
Indicator light C): Fault indicator:
- 2 flashes, minor leak alarm:
Minor leaks detected or water nozzle clogged: the high pressure
washer shuts down.
- 3 flashes, no water alarm:
After 3 minutes of operation with no water detected, the high
pressure washer shuts down.
- 4 flashes, motor thermal protector activated:
The high pressure washer shuts down.
- 5 flashes, anti-flood system activated:
After 1 hour of non-stop operation, the high pressure washer
shuts down.
Indicator light D): 200h programmed maintenance interval
expired. The light will go off following maintenance by the
authorised service centre.
English
N.B. To reset the fault si-
gnals, turn main switch "A"
to pos. "0" and then back
to pos. "I".
A
For further assistance, con-
tact the technical service
centre.

IMPORTANT!

To eliminate any impurities
B C D
or air bubbles from the wa-
ter circuit we advise starting
the cleaner for the first time
without the lance and letting
FIG. 6
the water run out for a few
seconds.
Impurities could block the
nozzle and cause malfun-
ction (Fig. 7).
USING THE ACCESSORIES.
The high pressure washer
has a nozzle with a flat jet for
cleaning large surfaces.
!
Aim the jet from a certain
distance to avoid damage
caused by the high pressure.
ROTARY HEAD (optional accessory)
The high pressure washer can be fitted with a head with rotary
nozzle to clean the most stubborn dirt.
!
Aim the jet from a certain distance to avoid damage caused by
the high pressure.
Do not aim the jet at people, animals or electrical sockets.
STOPPING THE CLEANER
1) After using with detergent, flush out the intake circuit; place
the detergent suction hose (fig. 8) in a tank of clean water and
let the pump run for 1 minute with the dosing tap turned fully
on and the lance in detergent delivery condition.
2) Stop the cleaner by turning the selector switch to pos. "0"
(fig. 6A).
3) Discharge the pressure from the H.P. hose by pressing the
trigger on the gun (fig. 5A).
4) Disconnect the water cleaner from the mains electricity
supply via the omnipolar switch or by unplugging the plug from
the socket.
5) Turn off the water supply tap (fig. 4A).
!
- If the water cleaner is left, even temporarily, turn it off by using
the omnipolar switch or by unplugging the plug from the socket.
- 22 -
Warning
Danger:
Warning
FIG. 7
FIG. 8

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Press-cPw-c45Pw-c55

Tabla de contenido