Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Before carrying out any operations, disconnect the cleaner from the power
(via the omnipolar switch or by unplugging the plug from the socket) and water supply.
FAULTS
When the switch is turned the cleaner
does not start.
No water jet is produced or there is a
leak from the high pressure water cir-
cuit; after 3 minutes the high pressure
washer shuts down and indicator light
"C" flashes.
The pump turns but does not reach the
rated pressure.
With the lance open, the pressure rises
and falls. After 10 pulses, the high pres-
sure washer shuts down and indicator
light "C" flashes.
In bypass or total stop mode, the high
pressure washer shuts down and indi-
cator light "C" flashes.
Following a total stop, the high pressure
washer fails to start and indicator light
"B" flashes.
Insufficient detergent suction.
Presence of water in oil.
Water leaks from head.
N.B. To reset the fault signals, turn main switch "A" to pos."0" and then back to pos. "I".
For maintenance and/or repairs, use only original spare parts which offer the greatest characteristics of quality and
reliability. Failure to use original spare parts frees the manufacturer from all responsibility.
English

TROUBLE-SHOOTING

CAUSES
Faulty electric connection.
(Indicator light "B" off).
Thermal protection has tripped.
(Indicator light "C" off).
The omnipolar switch has tripped.
Faulty water circuit connection.
Clogged water filter.
Mains tap turned off.
Leaks from the high pressure circuit.
Water intake filter blocked.
Faulty water circuit connection.
Pressure regulation valve is set at
minimum.
Lance nozzle is worn.
Detergent intake device on the lance is
turned on.
Dirty or worn valves.
The nozzle is clogged or deformed.
Insufficient supply.
Micro-leaks of water from the high pres-
sure circuit.
The high pressure washer is not used for
at least 20 minutes and goes into total
stop mode. (TSI)
No detergent in the tank.
Control on the lance not switched on.
Oil seal rings worn.
Gaskets worn.
IMPORTANT:
- 26 -
REMEDIES
Check the mains voltage.
Reset (if it trips again, apply to the
technical service centre).
Reset (if it trips again, apply to the
technical service centre).
Check it.
Clean it.
Turn it on.
Contact a technical service centre.
Clean it.
Check it.
Regulate it.
Apply to our technical service centre.
Turn it off.
Apply to our technical service centre.
Clean or consult our technical service
centre.
Check it.
Contact a technical service centre.
Restart by turning main switch "A" to pos.
"0" and then back to pos. "I".
Fill the detergent tank.
Set the control on the lance.
Apply to our technical service centre.
Apply to our technical service centre.

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Press-cPw-c45Pw-c55

Tabla de contenido