Updating Analyzer

The analyzer must be updated to cover
the latest cordless power tools or new
batteries and additional diagnostic
functions. The update can be performed
as described below.
Direct update with diagnostic software
and internet access
Computer with diagnostic software has
access to internet – see "Diagnostic
Software":
Connect analyzer to the computer
N
with the USB cable.
In the menu, click on button "Check for
updates... ". The diagnostic software
checks whether an update is available. If
yes, the update is performed
automatically.
Indirect update (without computer)
Data for updating the analyzer is
supplied by the subsidiary.
ADG 2

Testing Cordless Power Tool

Connect the analyzer to the power
N
supply – see "Connecting Analyzer
to Power Supply".
Operate the analyzer only in enclosed
and dry rooms at ambient temperatures
between 41°F (5°C) and 104°F (40°C).
Operating instructions
The analyzer is operated with two
pushbuttons (1):
To confirm procedures during test
To scroll between display pages
during test
To select language
To clear the fault memory
Insert battery
A STIHL type AP battery with a minimum
charge of 80% is required to test the
cordless power tool. The battery
supplies the cordless power tool with the
power needed for the test.
Push the battery (1) into the
N
analyzer (2) until you feel noticeable
resistance – then push it as far as
stop.
The contacts on the battery and
analyzer must be clean.
The test continues automatically when
the battery is inserted. If the test does
not continue, the reason may be:
1
No contact between battery and
analyzer – remove the battery and
refit it.
Fault in battery – test with STIHL
ADG 1 battery analyzer if
necessary.
If the battery's state of charge is too low,
the analyzer's display shows:
State of charge too low
Use a properly charged battery.
N
Insert adapter
Inserting the adapter connects the
cordless power tool to the battery. The
cordless power tool is ready for
operation.