Contents
1. Safety precautions ........................................................................................2
Note: This symbol mark is for EU countries only.
This symbol mark is according to the directive 2012/19/EU Article 14 Information for users and Annex IX.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
Please, dispose of this equipment at your local community waste collection/recycling centre.
In the European Union there are separate collection systems for used electrical and electronic product.
Please, help us to conserve the environment we live in!
Caution:
• Do not vent R410A into the Atmosphere:
■ Heat pumps certification
The mark "NF Heat pumps" is an independent certification program proving that heat pumps' performances and production quality of the factory are
conformed with the certification reference NF-414. The combinations of indoor units and outdoor units, and their applications allowed to use the NF PAC mark
can be consulted on the website www.marque-nf.com
1. Safety precautions
► Before installing the unit, make sure you read all
the "Safety precautions".
► Please report to or take consent by the supply au-
thority before connection to the system.
Warning:
Describes precautions that must be observed to pre-
vent danger of injury or death to the user.
Caution:
Describes precautions that must be observed to pre-
vent damage to the unit.
Warning:
• The unit must not be installed by the user. Ask a
dealer or an authorized technician to install the unit.
If the unit is installed incorrectly, water leakage,
electric shock, or fire may result.
• For installation work, follow the instructions in the
Installation Manual and use tools and pipe compo-
nents specifically made for use with R410A refrig-
erant. The R410A refrigerant in the HFC system is
pressurized 1.6 times the pressure of usual refrig-
erants. If pipe components not designed for R410A
refrigerant are used and the unit is not installed cor-
rectly, the pipes may burst and cause damage or
injuries. In addition, water leakage, electric shock,
or fire may result.
• The unit must be installed according to the instruc-
tions in order to minimize the risk of damage from
earthquakes, typhoons, or strong winds. An incor-
rectly installed unit may fall down and cause dam-
age or injuries.
2
6. Water piping work .........................................................................................10
7. Electrical work ..............................................................................................10
8. Special Functions .........................................................................................12
9. System control .............................................................................................12
10. Specifications .............................................................................................12
11. Serial number .............................................................................................. 13
After installation work has been completed, explain the
"Safety Precautions," use, and maintenance of the unit to
the customer according to the information in the Operation
Manual and perform the test run to ensure normal opera-
tion. Both the Installation Manual and Operation Manual
must be given to the user for keeping. These manuals
must be passed on to subsequent users.
: Indicates a part which must be grounded.
Warning:
Carefully read the labels affixed to the main unit.
• The unit must be securely installed on a structure
that can sustain its weight. If the unit is mounted on
an unstable structure, it may fall down and cause
damage or injuries.
• If the outdoor unit is installed in a small room,
measures must be taken to prevent the refriger-
ant concentration in the room from exceeding the
safety limit in the event of refrigerant leakage. Con-
sult a dealer regarding the appropriate measures
to prevent the allowable concentration from being
exceeded. Should the refrigerant leak and cause the
concentration limit to be exceeded, hazards due to
lack of oxygen in the room may result.
• Ventilate the room if refrigerant leaks during opera-
tion. If refrigerant comes into contact with a flame,
poisonous gases will be released.