Installation Location - Mitsubishi Electric PUHZ-SW-AA Serie Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47

2. Installation location

D
B
Fig. 2-1
Fig. 2-2
A
E
C
2.1. Refrigerant pipe (Fig. 2-1)
► Check that the difference between the heights of the indoor and outdoor
units, the length of refrigerant pipe, and the number of bends in the pipe
are within the limits shown below.
A Pipe length
Model
SW75
SW100
SHW80, 112
• Height difference limitation is defined regardless of which unit, indoor or outdoor,
is positioned higher.
D Indoor unit
E Outdoor unit
(mm)
2.2. Choosing the outdoor unit installation location
• Avoid locations exposed to direct sunlight or other sources of heat.
• Select a location from which noise emitted by the unit will not inconvenience
neighbors.
• Select a location permitting easy wiring and pipe access to the power source and
indoor unit.
• Avoid locations where combustible gases may leak, be produced, flow, or ac-
cumulate.
• Note that water may drain from the unit during operation.
• Select a level location that can bear the weight and vibration of the unit.
• Avoid locations where the unit can be covered by snow. In areas where heavy
snow fall is anticipated, special precautions such as raising the installation loca-
tion or installing a hood on the air intake must be taken to prevent the snow from
blocking the air intake or blowing directly against it. This can reduce the airflow
and a malfunction may result.
• Avoid locations exposed to oil, steam, or sulfuric gas.
• Use the transportation handles of the outdoor unit to transport the unit. If the unit
is carried from the bottom, hands or fingers may be pinched.
2.3. Outline dimensions (Outdoor unit) (Fig. 2-2)
B Height
(one way)
difference
2 m - 40 m
Max. 30 m
2 m - 75 m
Max. 30 m
2 m - 75 m
Max. 30 m
C Number of bends
(one way)
Max. 15
Max. 15
Max. 15
5

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido