First aid: Apply a few drops of sterile mineral oil to the eyes or a weak boric acid solution or
2% common salt solution. Subsequently rinse out eyes.
Please note
Please comply in full with the following safety information in order to exclude the danger of
property damage and damage to the environment!
Disruptions
If the refrigerating system fails to operate
check whether the current entry has been interrupted. This calls for troubleshooting by
technical experts!
If both refrigerating tongs fail to ice over
check whether the refrigerating machine is running and if the condenser is being aerated
adequately (is not contaminated, ventilation slots not displaced). If this should be the case,
troubleshooting needs to be carried out by a technical expert (cooling device constructor,
refrigeration technician)!
If only one of the refrigerating tongs ices over
hold both refrigerating tongs upright for about 10 minutes while the machine is running so
that any process oil that may have become displaced in the refrigerating tongs is led back to
the compressor. If this does not lead to a change, a technical expert should be asked to carry
out troubleshooting.
If the refrigerating system shuts down for no recognisable reason this could be due to
unduly high process temperatures or electric currents as a result of excessively high or low
ambient temperatures
inadequate air flow (air grille displaced, condenser contaminated)
electric failure.
Troubleshooting must be carried out by a technical expert if the equipment temperature was
maintained upon commissioning (min. 10° C), the ambient temperatures are within the
permissible limits and the air flow is correct.
In the event of a fire
Shut down the refrigerating system and use a carbon dioxide or powder fire extinguisher to
fight the fire.
General information
Only carry out freezing in compliance with the intended use described in the operating
manual.
Do not obstruct the air circulation, i.e. do not close the lid and block the ventilation slots
during operation as otherwise the freezing process cannot be carried out properly.
Protect cooling hoses and refrigerating tongs against damage.
Only store, transport and operate the pipe freezing system in the installation position. Protect
against impact, strong vibrations and falling. The system is suitable for portable use
according to class 7M2.
The installation location must be dry and free from dust.