Prescribed usage
The ROCAM® TV inspection system is intended exclusively for inspecting vacant and clean tubes, hollow
bodies and cavities, as stated under „Specifications / Fields of application". No other use is permissible.
All applicable standards and regulations must be complied with.
More specifically, these include:
Law governing technical equipment (equipment safety law) and appurtenant regulations
Low voltage directive
UVV VBG 1 "General regulations"
UVV VBG 4 "Electrical installations and operating equipment"
Directives governing work in containers and restricted areas (BG rule 77), directive on display
workstations.
Specifications / Fields of application
Description.................................................................................... ROCAM® mobile color
Video input ................................................................................... BNC 1 k
Video output................................................................................. BNC 75
Power consumption ...................................................................... 550 mA
Ambient temperature ................................................................... -10 ... +50 °C
Storage temperature ..................................................................... -30 ... +50 °C
Dimensions (L x W x H) ................................................................. 510 x 415 x 365 mm
Weight inc. Battery ....................................................................... 13 kg
Monitor ........................................................................................ color display screen 5.6"
Camera module ............................................................................ type CMOS color PAL, NTSC
Camera head diameter.................................................................. ø 33 mm
Reel cable length........................................................................... 36 m
Reel cable diameter....................................................................... ø 4.5 mm
Battery voltage.............................................................................. 18 V
Battery capacity............................................................................. 1.4 Ah
Tube ø .......................................................................................... 33-150 mm
Tube ø with mini module (optional) .............................................. 25-100 mm
Scope of supply: TV inspection system, guide pieces, instruction manual, video cable (SCART), battery,
power supply unit – electrical connection: 100 to 240 V~ / 50 to 60 Hz
Equipment voltage: 24 V / 1,00 A. Equivalent power supply unit as an alternative
Operating instructions
Do not buckle the reel cable as it may break!
Do not pull the reel cable over sharp edges as they
may damage the cable!
Never aim jets of water on the front (display
screen/ control panel) of the equipment!

Power connection

A new battery must be charged prior to using it for
the first time (approx. 7h).
If the battery is running low, the power supply unit
should be connected. The charging process takes
less time if the equipment is switched off.
10
The power supply unit can be connected
permanently.
The battery cannot be overcharged. Once the
battery is sufficiently charged, the system
automatically switches to float charging.
When the power supply unit is connected the
batterycharge warning lamp is illuminated.
A
Red: Battery discharged (< 70%) -> fast charge.
Green: Battery charged (> 70%) -> float charging.
When the ROCAM® is switched on the device
always switches to float charging irrespective of
the degree of charge or discharge of the battery.