Electrical
Disconnect power before working on pump, motor, pressure switch, or wiring .
Motor Switch Settings
NOTICE: 1/2 HP motors are dual voltage and are factory set to 115 V. 3/4 & 1 HP motors are also dual voltage, but are
factory set to 230 V. Motor terminal boards (located under the motor end cover) should look like one of those below.
Use the instructions to set your motor to match your power source.
Risk of electric shock . Never connect a motor set to 115 V to a 230 V power source.
Plug Type Voltage Selector
Voltage Change Plug
Ground Wire Connection
Figure 14: Voltage set to 230 V, Plug Type
Voltage is set to 230 V . To change to 115 V:
1. Make sure power is off.
2. Pull the voltage change plug off of the tabs.
3. Move the voltage change plug to the 115 V position.
The plug will now cover 2 metal tabs and the arrow
on the plug will line up with the 115 V arrow on the
label (see Figure 15).
Figure 15: Voltage set to 115 V, Plug Type
4. Attach the incoming power leads to the two outer
screws on the pressure switch as shown in Figure 14.
5. Attach the ground wire to one of the grounding
connections, shown in Figure 14.
6. If there are other wires, they should be capped.
7. Reinstall the motor end and pressure switch covers.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Power Connections
Pressure Switch
Dial Type Voltage Selector
Power Supply Connections
Voltage
Change
Dial
Ground Wire Connection
Figure 16: Voltage set to 230 V, Dial Type
Voltage is set to 230 V . To change to 115 V:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in
the dial window as shown in Figure 17.
Figure 17: Voltage set to 115 V, Dial Type
3. Attach the incoming power leads to the two outer
screws on the pressure switch as shown in Figure 16.
4. Attach the ground wire to the grounding connections
as shown in Figure 16.
5. If there are other wires, they should be capped.
6. Reinstall the motor end and pressure switch covers.
9
Pressure Switch